Show simple item record

dc.contributor.authorLIZE, Emmanuel
dc.contributor.authorREBILLAT, Marc
dc.contributor.author
 hal.structure.identifier
MECHBAL, Nazih
86289 Laboratoire Procédés et Ingénierie en Mécanique et Matériaux [PIMM]
dc.date.accessioned2017
dc.date.available2017
dc.date.issued2017
dc.date.submitted2017
dc.identifier.urihttp://hdl.handle.net/10985/12044
dc.description.abstractThe influence of temperature on SHM (Structural Health Monitoring) systems using guided waves is a major problem for their industrial deployment. One of the most used and cheapest SHM process developed in aeronautic context is based on piezoelectric transducers mounted on the monitored structure. Several methods are then used to assess the presence of damage. A popular one is based on tracking changes in the static capacity of the transducers: it is an efficient damage indicator in close area surrounding the device and is often used as a fault diagnosis of the transducer itself. However, monitoring decision are robustified with temperature sensors also mounted on the structure, adding wires and signal processing post-treatments. In this article, the static capacity is used to determine the temperature on each lead zirconate titanate transducer (PZT). By imparting this additional functionality to PZT devices, supplementary instrumentation is not necessary and an estimation of the entire temperature field of the structure is obtained. The original proposed approach is tested experimentally on a on a small composite plate and then on a large real part of an A380 composite nacelle. The results show that the temperature field on the structure can be estimated with a precision of ±5 °C using a linear regression between static capacity and temperature
dc.language.isoen
dc.rightsPost-print
dc.subjectaerospace, health monitoring and diagnosis, smart sensors and actuators, networks of sensors and actuators, piezoceramic devices, temperature effect, electromechanical signature
dc.titleEstimation of the temperature field on a composite fan cowl using the static capacity of surface-mounted piezoceramic transducers
dc.typdocCommunication avec acte
dc.localisationCentre de Paris
dc.subject.halSciences de l'ingénieur: Mécanique: Vibrations
dc.subject.halSciences de l'ingénieur: Traitement du signal et de l'image
ensam.audienceNon spécifiée
ensam.conference.title20th IFAC World Congress
ensam.conference.date2017
ensam.countryFrance
ensam.title.proceeding20th IFAC World Congress
ensam.page1-7
ensam.cityToulouse
ensam.peerReviewingOui
ensam.invitedCommunicationNon
ensam.proceedingOui
hal.identifierhal-01593482
hal.version1
hal.submission.permittedupdateFiles
hal.statusreplace


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record