Afficher la notice abrégée

dc.contributor.author
 hal.structure.identifier
PIETTON, Raphael
466360 Institut de Biomecanique Humaine Georges Charpak
dc.contributor.authorBOULOUSSA, Houssam
dc.contributor.authorSKALLI, Wafa
dc.contributor.authorVIALLE, Raphaël
dc.contributor.author
 hal.structure.identifier
VERGARI, Claudio
1001017 Institut de Biomécanique Humaine Georges Charpak [IBHGC]
dc.date.accessioned2
dc.date.available2020
dc.date.issued2020
dc.date.submitted2018
dc.identifier.issn0271-6798
dc.identifier.urihttp://hdl.handle.net/10985/13174
dc.description.abstractStudy design: A reproducibility study of preoperative rib cage 3D measurements was conducted for patients with Adolescent Idiopathic Scoliosis (AIS). Objective: to assess the reliability of rib cage 3D reconstructions using biplanar stereoradiography in patients with AIS before surgery. Summary: no prior reliability study has been performed for preoperative 3D reconstructions of the rib cage by using stereoradiography in patients with preoperative AIS. Materials: this series includes 21 patients with Lenke 1 or 2 scoliosis (74°+ - 20). All patients underwent low-dose standing biplanar radiographs. Two operators performed reconstructions twice each. Intraoperator repeatability, interoperator reproducibility and Intraclass coefficients (ICC) were calculated and compared between groups. Results: The average rib cage volume was 4.7l L (SD ± 0.75 L). SDr was 0.19 L with a coefficient of variation of 4.1% ; ICC was 0.968. The thoracic index was 0.6 (SD ± 0.1). SDr was 0.03 with a coefficient of variation of 4.7 % and a ICC of 0.820. As for the Spinal Penetration Index (6.4% ; SD ± 2.4), SDr was 0.9 % with a coefficient of variation of 14.3 % and a ICC of 0.901. The 3D rib hump SDr (average 27° ± 8°) was 1.4°. The coefficient of variation and ICC were respectively 5.1% and 0.991. Conclusion: 3D reconstruction of the rib cage using biplanar stereoradiography is a reliable method to estimate preoperative thoracic parameters in patients with AIS.
dc.language.isoen
dc.publisherLippincott, Williams & Wilkins
dc.rightsPost-print
dc.subjectThree dimensional reconstruction, rib cage, scoliosis
dc.titleRib Cage Measurement Reproducibility Using Biplanar Stereoradiographic 3D Reconstructions in Adolescent Idiopathic Scoliosis
dc.identifier.doi10.1097/BPO.0000000000001095
dc.typdocArticle dans une revue avec comité de lecture
dc.localisationCentre de Paris
dc.subject.halSciences du vivant: ingénierie bio-médicale
ensam.audienceInternationale
ensam.page36-41
ensam.journalJournal of Pediatric Orthopedics
ensam.volume40
ensam.peerReviewingOui
dcterms.publisherWolters kluwer
hal.statusunsent


Fichier(s) constituant cette publication

Thumbnail

Cette publication figure dans le(les) laboratoire(s) suivant(s)

Afficher la notice abrégée