Show simple item record

dc.contributor.author
 hal.structure.identifier
MEKRI, Fatiha
13094 Institut de Recherche de l'Ecole Navale [IRENAV]
dc.contributor.author
 hal.structure.identifier
CHARPENTIER, Jean-Frederic
13094 Institut de Recherche de l'Ecole Navale [IRENAV]
dc.contributor.author
 hal.structure.identifier
SEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
dc.contributor.authorKESTELYN, Xavier
dc.date.accessioned2013
dc.date.available2013
dc.date.issued2012
dc.date.submitted2013
dc.identifier.issn2103-364
dc.identifier.otherhttp://ejee.revuesonline.com/article.jsp?articleId=17687
dc.identifier.urihttp://hdl.handle.net/10985/6881
dc.descriptionLa version éditeur de cet article est accessible à l'adresse suivante : doi:10.3166/ejee.15.377-400
dc.description.abstractThe use of multiphase PM synchronous machines associated with VSI drives appears to be a very efficient solution when a high level of reliability, compactness and acoustic behaviour is required. This kind of solution is for example very useful in naval propulsion systems. The paper deals with the optimal control of a 5-phase PM machine associated with a VSI under fault conditions. This work focus on the use of such a system in normal and fault operations. The studied fault operations are open circuited phase fault conditions. Previous works have shown that, with this kind of 5-phase drive, it is possible to determine optimal currents references which maximize the torque density and reduce the torque pulsations of the machine when one or two phases are open circuited. In this fault case, classical linear controllers (as PID for example) cannot provide a correct tracking of these optimal reference currents because they have a highly dynamical behavior. Using this optimal reference current generation, we propose in this paper to compare classical PID controllers with fixed band and adaptive band hysteresis controllers. This comparison is done using Matlab/Simulink simulation in the case of a 5 phase surface mounted permanent magnet machine in normal and open-circuited fault operations. Study results show that adaptive band hysteresis control allows a good tracking of these unconventional reference currents with a fixed switching frequency for the VSI. In this case of adaptive s band hysteresis control appears to be particularly efficient.
dc.publisherHERMES
dc.rightsPost-print
dc.subjectmulti phase machine
dc.subjectfault tolerant
dc.subjectnonlinear control
dc.subjecton line strategy
dc.subjectcurrent reference
dc.titleÉtude comparative de différents correcteurs pour la commande optimale avec défauts d’une machine pentaphasée
dc.identifier.doi10.3166/ejee.15.377-400
dc.typdocArticle dans une revue avec comité de lecture
dc.localisationCentre de Lille
dc.subject.halSciences de l'ingénieur: Automatique / Robotique
dc.subject.halSciences de l'ingénieur: Energie électrique
ensam.audienceInternationale
ensam.page377-400
ensam.journalÉtude comparative de différents correcteurs pour la commande optimale avec défauts d’une machine pentaphasée
ensam.volume15
ensam.issue4
hal.identifierhal-00804468
hal.version1
hal.statusaccept


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record