Show simple item record

dc.contributor.authorBAYEUL-LAINE, Annie-Claude
dc.contributor.authorDUPONT, Patrick
dc.contributor.authorCAVAZZINI, Giovanna
dc.contributor.authorCHERDIEU, Patrick
dc.contributor.authorBOIS, Gérard
dc.contributor.authorROUSSETTE, Olivier
dc.contributor.author
 hal.structure.identifier
DAZIN, Antoine
1252 Laboratoire de Mécanique de Lille - FRE 3723 [LML]
dc.date.accessioned2013
dc.date.available2013
dc.date.issued2013
dc.date.submitted2013
dc.identifier.urihttp://hdl.handle.net/10985/7458
dc.description.abstractThe paper presents the analysis of the performance and the internal flow behaviour in the vaned diffuser of a radial flow pump using PIV technique, pressure probe traverses and numerical simulations. PIV measurements have been performed at different heights inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, PIV measurements have been made for different angular positions of the impeller. For each angular position, instantaneous velocities charts have been obtained on two simultaneous views, which allows, firstly, to cover the space between the leading edge of the impeller and the diffuser throat and secondly, to get a rather good evaluation of phase averaged velocity charts and “fluctuating rates “. Probe traverses have also been performed using a 3 holes pressure probe from hub to shroud diffuser width at different radial locations in between the two diffuser geometrical throats. The numerical simulations were realized with the two commercial codes: i-Star CCM+ 7.02.011 (at LML), ii-CFX 10.0 (at University of Padova). Fully unsteady calculations of the whole pump were performed. Comparisons between numerical and experimental results are presented and discussed for two flow rates. In this respect, the effects of fluid leakage due to the gap between the rotating and fixed part of the pump model are analysed and discussed.
dc.language.isoen
dc.rightsPost-print
dc.subjectPump
dc.subjectDiffuser
dc.subjectPIV measurements
dc.subjectNumerical calculations
dc.subjectProbes
dc.titleNUMERICAL AND EXPERIMENTAL INVESTIGATIONS IN A VANED DIFFUSER OF SHF IMPELLER: FLUID LEAKAGE EFFECT
dc.typdocCommunication avec acte
dc.localisationCentre de Lille
dc.subject.halMathématique: Probabilités
dc.subject.halMathématique: Analyse numérique
ensam.audienceNationale
ensam.conference.titleCongrès français de mécanique (21 ; 2013 ; Bordeaux (Gironde)).
ensam.conference.date2013-11-26
ensam.countryFrance
ensam.title.proceedingCongrès français de mécanique (21 ; 2013 ; Bordeaux (Gironde)).
ensam.page1-6
hal.identifierhal-00879761
hal.version1
hal.submission.permittedupdateMetadata
hal.statusaccept


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record