dc.description.abstractDamage mechanisms of injection molded polyamide-66/short glass fiber 30 wt% composite (PA66/GF30) were analyzed using in situ SEM mechanical tests on specimens conditioned under three relative humidity contents (RH = 0%, 50% and 100%). The validity of these in situ analyses was confirmed by Xray micro-computed tomography (lCT) observations on tensile loaded specimens. Experimental results demonstrated that relative humidity (RH) conditions influence strongly the damage level and damage mechanisms. Indeed, for specimen with RH = 0%, damage initiation occurs at significantly higher load level than those in RH = 50% and RH = 100% specimens. The higher relative humidity condition also results in higher damage level. Damage chronologies have been proposed as damage initiation in the form of fiber–matrix debonding occurs at fiber ends and more generally at locations where fibers are close to each other due to the generation of local stress concentration (for all studied RH contents), and first fiber breakages occur (RH = 0%). These debonded zones further propagate through fiber–matrix interface (for all studied RH contents), and new fiber breakages develop (RH = 0%). At high relative flexural stress, matrix microcracks appear and grow regardless the RH contents. For RH = 100%, these microcracks are also accompanied by many matrix deformation bands. Subsequently, they lead to the damage accumulation and then to the final failure.
dc.description.sponsorshipProjet FUI-DGSIS "DURAFIP"
dc.language.isoen
dc.publisherElsevier
dc.rightsPost-print
dc.subjectPolymer–matrix composites (PMCs)
dc.subjectDebonding
dc.subjectFiber–matrix bond
dc.subjectElectron microscopy Relative humidity
dc.titleIn situ damage mechanisms investigation of PA66/GF30 composite: Effect of relative humidity
dc.identifier.doi10.1016/j.compositesb.2013.11.001
dc.typdocArticle dans une revue avec comité de lecture
dc.localisationCentre de Metz
dc.subject.halSciences de l'ingénieur: Matériaux
dc.subject.halSciences de l'ingénieur: Mécanique
dc.subject.halSciences de l'ingénieur: Mécanique: Matériaux et structures en mécanique
dc.subject.halSciences de l'ingénieur: Mécanique: Mécanique des matériaux
dc.subject.halSciences de l'ingénieur: Mécanique: Mécanique des solides
ensam.audienceInternationale
ensam.page487-495
ensam.journalComposites Part B: Engineering
ensam.volume58
hal.statusunsent
dc.identifier.eissn1879-1069


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record