<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>SAM</title>
<link>https://sam.ensam.eu:443</link>
<description>The DSpace digital repository system captures, stores, indexes, preserves, and distributes digital research material.</description>
<pubDate xmlns="http://apache.org/cocoon/i18n/2.1">Fri, 05 Jun 2026 22:00:43 GMT</pubDate>
<dc:date>2026-06-05T22:00:43Z</dc:date>
<item>
<title>Distribution and variability study of the femur cortical thickness from computer tomography</title>
<link>http://hdl.handle.net/10985/20222</link>
<description>Distribution and variability study of the femur cortical thickness from computer tomography
SERRURIER, Antoine; JOLIVET, Erwan; QUIJANO, Sergio; THOREUX, Patricia; SKALLI, Wafa
In the context of patient-specific 3D bone reconstruction, enhancing the surface with cortical thickness (COT) opens a large field of applications for research and medicine. This functionality calls for database analysis for better knowledge of COT. Our study provides a new approach to reconstruct 3D internal and external cortical surfaces from computer tomography (CT) scans and analyses COT distribution and variability on a set of asymptomatic femurs. The reconstruction method relies on a short (∼5 min) initialisation phase based on 3D reconstruction from biplanar CT-based virtual X-rays and an automatic optimisation phase based on intensity-based cortical structure detection in the CT volume, the COT being the distance between internal and external cortical surfaces. Surfaces and COT show root mean square reconstruction errors below 1 and 1.3 mm. Descriptions of the COT distributions by anatomical regions are provided and principal component analysis has been applied. The first mode, 16–50% of the variance, corresponds to the variation of the mean COT around its averaged shape; the second mode, 9–28%, corresponds to a fine variation of its shape. A femur COT model can, therefore, be described as the averaged COT distribution in which the first parameter adjusts its mean value and a second parameter adjusts its shape.
</description>
<pubDate>Sun, 01 Jan 2012 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://hdl.handle.net/10985/20222</guid>
<dc:date>2012-01-01T00:00:00Z</dc:date>
<dc:creator>SERRURIER, Antoine</dc:creator>
<dc:creator>JOLIVET, Erwan</dc:creator>
<dc:creator>QUIJANO, Sergio</dc:creator>
<dc:creator>THOREUX, Patricia</dc:creator>
<dc:creator>SKALLI, Wafa</dc:creator>
<dc:description>In the context of patient-specific 3D bone reconstruction, enhancing the surface with cortical thickness (COT) opens a large field of applications for research and medicine. This functionality calls for database analysis for better knowledge of COT. Our study provides a new approach to reconstruct 3D internal and external cortical surfaces from computer tomography (CT) scans and analyses COT distribution and variability on a set of asymptomatic femurs. The reconstruction method relies on a short (∼5 min) initialisation phase based on 3D reconstruction from biplanar CT-based virtual X-rays and an automatic optimisation phase based on intensity-based cortical structure detection in the CT volume, the COT being the distance between internal and external cortical surfaces. Surfaces and COT show root mean square reconstruction errors below 1 and 1.3 mm. Descriptions of the COT distributions by anatomical regions are provided and principal component analysis has been applied. The first mode, 16–50% of the variance, corresponds to the variation of the mean COT around its averaged shape; the second mode, 9–28%, corresponds to a fine variation of its shape. A femur COT model can, therefore, be described as the averaged COT distribution in which the first parameter adjusts its mean value and a second parameter adjusts its shape.</dc:description>