Influence of design parameters on the global performances of low-speed counter-rotating axial-flow fans
dc.contributor.author | WANG, Juan |
dc.contributor.author
hal.structure.identifier | RAVELET, Florent
|
dc.contributor.author | BAKIR, Farid |
dc.date.accessioned | 2014 |
dc.date.available | 2017 |
dc.date.issued | 2014 |
dc.date.submitted | 2014 |
dc.identifier.uri | http://hdl.handle.net/10985/8579 |
dc.description.abstract | The present work aims at experimentally investigating the effects of some parameters on the performances of a counter-rotating stage, and on the instationary flow between the rotors. Three counter-rotating fans, which have the same design point, have been designed. These systems differ by the distribution of the loading and of the ratio of angular velocity between the front rotor and the rear rotor. All the configurations have been tested in a normalized test rig, where the ratio of angular velocities and the axial distance between the two rotors can be varied. The influence of these parameters are then addressed by analysing the experimental results of the static pressure rise and static efficiency, as well as of the wall pressure fluctuations registered by a microphone at the wall. The three systems achieve the design point with a high efficiency. The counter-rotating systems lead to at least a 10 percentage points gain in static efficiency at the design flow rate, compared to the typical peak efficiency of a traditional rotor-stator stage. Meanwhile, counter-rotating systems display good working stabilities at very low volume flow rates. In addition, at the design speed ratio, the overall performance decreases almost monotonically with the axial distance. Nevertheless, an optimum in axial distance can be found for higher speed ratios. Finally, the investigations of the wall pressure fluctuations show that the amplitudes of power spectral density corresponding to the blade passing frequency of the rear rotor are significantly higher than that of the front rotor. The interaction peaks are also stronger for an equal distribution of the work on the two rotors. |
dc.language.iso | en_US |
dc.rights | Post-print |
dc.title | Influence of design parameters on the global performances of low-speed counter-rotating axial-flow fans |
ensam.embargo.terms | 50 years |
dc.typdoc | Communication avec acte |
dc.localisation | Centre de Paris |
dc.subject.hal | Sciences de l'ingénieur: Mécanique: Mécanique des fluides |
ensam.audience | Internationale |
ensam.conference.title | ASME 2014 4th Joint US-European Fluids Engineering Division Summer Meeting and 11th International Conference on Nanochannels, Microchannels, and Minichannels |
ensam.conference.date | 2014-08-04 |
ensam.country | United States |
ensam.title.proceeding | Proceedings of the ASME 2014 4th Joint US-European Fluids Engineering Division Summer Meeting and 11th International Conference on Nanochannels, Microchannels, and Minichannels |
ensam.page | FEDSM2014-22172 |
hal.status | unsent |