Quasi-automatic 3D reconstruction of the full spine from low-dose biplanar X-rays based on statistical inferences and image analysis
Article dans une revue avec comité de lecture
Auteur
Résumé
Purpose: To design a quasi-automated three-dimensional reconstruction method of the spine from biplanar X-rays as the daily used method in clinical routine is based on manual adjustments of a trained operator and the reconstruction time is more than 10 minutes per patient. Methods: The proposed method of 3D reconstruction of the spine (C3-L5) relies first on a new manual input strategy designed to fit clinicians’ skills. Then, a parametric model of the spine is computed using statistical inferences, image analysis techniques and fast manual rigid registration. Results: An agreement study with the clinically used method on a cohort of 57 adolescent scoliotic subjects has shown that both methods have similar performance on vertebral body position and axial rotation (null bias in both cases and standard deviation of signed differences of 1mm and 3.5° around respectively). In average, the solution could be computed in less than 5 minutes of operator time, even for severe scoliosis. Conclusions: The proposed method allows fast and accurate 3D reconstruction of the spine for wide clinical applications and represents a significant step toward full automatization of 3D reconstruction of the spine. Moreover, it is to the best of our knowledge the first method including also the cervical spine.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Vertebral rotation estimation from frontal X-rays using a quasi-automated pedicle detection method Article dans une revue avec comité de lectureEBRAHIMI, Shahin; SKALLI, Wafa; ANGELINI, Elsa D.; GAJNY, Laurent; VERGARI, Claudio (Springer Verlag, 2019)Purpose Measurement of vertebral axial rotation (VAR) is relevant for the assessment of scoliosis. Stokes method allows estimating VAR in frontal X-rays from the relative position of the pedicles and the vertebral body. ...
-
Article dans une revue avec comité de lectureQuantitative measurements of spine shape parameters on planar X-ray images is critical for clinical applications but remains tedious and with no fully-automated solution demonstrated on the whole spine. This study aims to ...
-
Communication avec acte3D reconstruction of the spine using biplanar X-rays remains approximate and requires human-machine interactions to adjust the position of important features such as vertebral corners and endplates. The purpose of this ...
-
Communication avec acteX-ray based quantitative analysis of spine parameters is required in routine diagnosis or treatment planning. Existing tools commonly require manual intervention. Attempts towards automation of the whole procedure have ...
-
Communication avec acteYANG, Zixin; SKALLI, Wafa; GAJNY, Laurent; ANGELINI, Elsa D.; VERGARI, Claudio (Springer International Publishing, 2019)Manually annotating medical images with few landmarks to initialize 3D shape models is a common practice. For instance, when reconstructing the 3D spine from biplanar X-rays, the spinal midline, passing through vertebrae ...