Experimental and ab initio infrared study of χ-, κ- and α-aluminas formed from gibbsite
Article dans une revue avec comité de lecture
Date
2010Journal
Journal of Solid State ChemistryRésumé
χ-, κ- and α-alumina phases formed by dehydration of micro-grained gibbsite between 773 and 1573 K are studied using infrared spectroscopy (IR). The structural transitions evidenced by X-ray diffraction (XRD) were interpreted by comparing IR measurements with ab initio simulations (except for the χ form whose complexity does not allow a reliable simulation). For each phase, IR spectrum presents specific bands corresponding to transverse optical (TO) modes of Al-O stretching and bending under 900 cm-1. The very complex χ phase, obtained at 773 K, provides a distinctive XRD pattern in contrast with the IR absorbance appearing as a broad structure extending between 200 and 900 cm-1 resembling the equivalent spectra for γ-alumina phase. κ-alumina is forming at 1173 K and its rich IR spectrum is in good qualitative agreement with ab initio simulations. This complexity reflects the large number of atoms in the κ-alumina unit cell and the wide range of internuclear distances as well as the various coordinances of both Al and O atoms. Ab initio simulations suggest that this form of transition alumina demonstrates a strong departure from the simple pattern observed for other transition alumina. At 1573 K, the stable α-Αl2Ο3 develops. Its IR spectra extends in a narrower energy range as compared to transition alumina and presents characteristics features similar to model α-Αl2Ο3{dot operator} Ab initio calculations show again a very good general agreement with the observed IR spectra for this phase. In addition, for both κ- and α-Αl2Ο3, extra modes, measured at high energy (above 790 cm-1 for κ and above 650 cm-1 for α), can originate from either remnant χ-alumina or from surface modes
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureAMIOT, Fabien; BORNERT, Michel; DOUMALIN, Pascal; DUPRE, Jean Christophe; FAZZINI, Marina; ORTEU, Jean José; POILANE, Christophe; ROBERT, Laurent; ROTINAT, René; TOUSSAINT, Evelyne; WATTRISSE, Bertrand; WIENIN, Jean Samuel (Wiley-Blackwell, 2013)We report on the main results of a collaborative work devoted to the study of the uncertainties associated with Digital image correlation techniques (DIC). More specifically, the dependence of displacement measurement ...
-
BrevetFILLEUL, Marie-Pierryle; LAHEURTE, Pascal; TERRASSE, Jean-Maxime; GEORGE, Olivier; PELTIER, Laurent (European Patent Office, 2015)Ressort d'orthodontie hélicoïdal et son procédé de fabrication
-
Communication avec acteMIQOI, Nada; POMAREDE, Pascal; MERAGHNI, Fodil; DECLERCQ, Nico Felicien; LECOZ, Gael; GUILLAUMAT, Laurent; DELALANDE, Stéphane (2019)Dans cette étude, des essais d’impacts à faible vitesse ont été réalisés sur un polyamide 6.6/6 renforcé de fibres de verre tissées. L’objectif principal est d’étudier qualitativement et quantitativement l’endommagement ...
-
Article dans une revue avec comité de lectureMIQOI, Nada; POMAREDE, Pascal; DECLERCQ, Nico Felicien; LE COZ, Gael; DELALANDE, Stéphane; GUILLAUMAT, Laurent; MERAGHNI, Fodil (SAGE Publications, 2020)The present experimental work investigates the response of woven glass fabric reinforced polyamide 6.6/6 subjected to drop weight impact loading. The main objective is the development and the introduction of a new experimental ...
-
Article dans une revue avec comité de lectureCOZ, Gaël Le; PELTIER, Laurent; PIQUARD, Romain; LAHEURTE, Pascal; D’ACUNTO, Alain (Elsevier BV, 2022)The success of biomedical implantation is linked to osseointegration, depending on the mechanical loading of the bone interface. The large difference in stiffness between the host bone (30 GPa) and the usual implant ...