Direct AC Voltage Control for Grid-Forming Inverters
Article dans une revue avec comité de lecture
Date
2019Journal
Journal of Power ElectronicsRésumé
Grid-forming inverters usually use inner cascaded controllers to regulate output AC voltage and converter output current. However, at the power transmission system level where the power inverter bandwidth is limited, i.e., low switching frequency, it is difcult to tune controller parameters to achieve the desired performances because of control loop interactions. In this paper, a direct AC voltage control-based state-feedback control is applied. Its control gains are tuned using a linear quadratic regulator. In addition, a sensitivity analysis is proposed to choose the right cost factors that allow the system to achieve the imposed specifcations. Conventionally, a system based on direct AC voltage control has no restriction on the inverter current. Hence, in this paper, a threshold virtual impedance has been added to the state-feedback control in order to protect the inverter against overcurrent. The robustness of the proposed control is assessed for diferent short-circuit ratios using smallsignal stability analysis. Then, it is checked in diferent grid topologies using time domain simulations. An experimental test bench is developed in order to validate the proposed control.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteQORIA, Taoufik; LI, Chuanyue; OUE, Ko; COLAS, Frédéric; GUILLAUD, Xavier; PREVOST, Thibault (IEEE PES PowerTech 2019, 2019)In the near future, power converters will be massively introduced in transmission grids due to renewable energy sources and high voltage direct current (HVDC) increase. Voltage Source Converter (VSC) control laws assume ...
-
Article dans une revue avec comité de lectureLI, Chuanyue; QORIA, Taoufik; COLAS, Frédéric; JUN, Liang; WENLONG, Ming; GUILLAUD, X.; GRUSON, Francois (MDPI, 2019)The dq impedance stability analysis for a grid-connected current-control inverter is based on the impedance ratio matrix. However, the coupled matrix brings difficulties in deriving its eigenvalues for the analysis based ...
-
Communication avec acteQORIA, Taoufik; COLAS, Frédéric; GUILLAUD, Xavier; DEBRY, Marie-Sophie; PREVOST, Thierry; GRUSON, Francois (IEEE, 2018)From the origin of the grid, energy has been delivered to electrical loads mainly by synchronous machines. All the main rules to manage the grid have been based on the electromechanical behavior of these machines which ...
-
Communication avec acteQORAI, Taoufik; GRUSON, François; COLAS, Frédéric; GUILLAUD, Xavier; DEBRY, M.-S.; PREVOST, T. (IEEE, 2018-06)From the origin of the grid, energy has been delivered to electrical loads mainly by synchronous machines. All the main rules to manage the grid have been based on the electromechanical behavior of these machines which ...
-
Article dans une revue avec comité de lectureQORIA, Taoufik; COLAS, Frédéric; DENIS, Guillaume; PREVOST, Thibault; GUILLAUD, Xavier; GRUSON, Francois (Institute of Electrical and Electronics Engineers, 2019)The present paper deals with the post-fault synchronization of a voltage source converter based on the droop control. In case of large disturbances on the grid, the current is limited via current limitation algorithms such ...