• français
    • English
    English
  • Ouvrir une session
Aide
Voir le document 
  •   Accueil de SAM
  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)
  • Voir le document
  • Accueil de SAM
  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)
  • Voir le document
JavaScript is disabled for your browser. Some features of this site may not work without it.

Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep.

Article dans une revue avec comité de lecture
Auteur
SCHOUMAN, Thomas
SCHMITT, Mary
ADAM, Clayton
DUBOIS, Guillaume
ccROUCH, Philippe
484605 LBM/institute de Biomécanique humaine Georges Charpak

URI
http://hdl.handle.net/10985/18003
DOI
10.1016/j.jmbbm.2016.02.036
Date
2016
Journal
Journal of the mechanical behavior of biomedical materials

Résumé

The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with load-bearing 'rigid' (high stiffness) porous implants on the right side, and with control on the left side. A second group of 6 ewes (group B) was treated with 'flexible' porous and control implants exhibiting apparent mechanical properties ten times lower than the rigid implants. The mechanical behavior of the reconstructed hemi-mandibles was assessed by cantilever testing and bone ingrowth into the segmental defects was assessed by BV/TV measurement within the implant using micro-CT 12 weeks after implantation. A significantly higher rigidity was identified for porous implants compared with control implants at the anterior interface in group B. BV/TV of porous implants was significantly higher than that of control implants in group A. BV/TV differences were significant between porous and control implants in group B and were homogeneous along the main axis. Significantly higher BV/TV was identified in most sub-volumes of group B porous implants compared with group A. This work highlights the critical importance of the tuning of scaffolds to promote bone ingrowth with reference to the local strains occurring within the porous scaffold, which in this application was achieved using fully load-bearing low-stiffness porous titanium implants.

Fichier(s) constituant cette publication

Nom:
IBHGC_JMBBM _2016_SCHOUMAN.pdf
Taille:
6.635Mo
Format:
PDF
Description:
Article
Voir/Ouvrir

Cette publication figure dans le(s) laboratoire(s) suivant(s)

  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)

Documents liés

Visualiser des documents liés par titre, auteur, créateur et sujet.

  • Fully automatic segmentation of craniomaxillofacial CT scans for computer-assisted orthognathic surgery planning using the nnU-Net framework 
    Article dans une revue avec comité de lecture
    DOT, Gauthier; SCHOUMAN, Thomas; DUBOIS, Guillaume; ccROUCH, Philippe; ccGAJNY, Laurent (Springer Science and Business Media LLC, 2022)
    Objectives To evaluate the performance of the nnU-Net open-source deep learning framework for automatic multi-task segmentation of craniomaxillofacial (CMF) structures in CT scans obtained for computer-assisted orthognathic ...
  • Diffusion model to describe osteogenesis within a porous titanium scaffold. 
    Article dans une revue avec comité de lecture
    SCHMITT, M.; ALLENA, Rachele; SCHOUMAN, T.; FRASCA, S.; COLLOMBET, J.M.; HOLY, X.; ccROUCH, Philippe (Taylor & Francis, 2015)
    In this study, we develop a two-dimensional finite element model, which is derived from an animal experiment and allows simulating osteogenesis within a porous titanium scaffold implanted in ewe's hemi-mandible during 12 ...
  • Evaluation of a Patient-Specific Finite-Element Model to Simulate Conservative Treatment in Adolescent Idiopathic Scoliosis 
    Article dans une revue avec comité de lecture
    RIBES, Gwenael; AUBERT, Benjamin; ADAM, Clayton; MILADI, Lotfi; ABELIN-GENEVOIS, Kariman; ccSKALLI, Wafa; ccROUCH, Philippe; ccVERGARI, Claudio (Springer Verlag, 2015)
    Study design: Retrospective validation study. Objectives: To propose a method to evaluate, from a clinical standpoint, the ability of a finite-element model (FEM) of the trunk to simulate orthotic correction of spinal ...
  • Spine 
    Chapitre d'ouvrage scientifique
    VAN DEN ABBEELE, Maxim; ADAM, Clayton; ccSKALLI, Wafa; ccLAPORTE, Sébastien; ccROUCH, Philippe; ccROHAN, Pierre-Yves (Elsevier, 2017)
    Clinical problems of the human spine have a high prevalence, affecting more than 25.5 million people in 2012. Older adults, in particular, are susceptible to degenerative spine disorders such as deformities or osteoporosis. ...
  • Inter-lamellar shear resistance confers compressive stiffness in the intervertebral disc: An image-based modelling study on the bovine caudal disc 
    Article dans une revue avec comité de lecture
    ADAM, Clayton; ccSKALLI, Wafa; ccROUCH, Philippe (Elsevier, 2016)
    The intervertebral disc withstands large compressive loads (up to nine times bodyweight in humans) while providing flexibility to the spinal column. At a microstructural level, the outer sheath of the disc (the annulus ...

Parcourir

Tout SAMLaboratoiresAuteursDates de publicationCampus/InstitutsCe LaboratoireAuteursDates de publicationCampus/Instituts

Lettre Diffuser la Science

Dernière lettreVoir plus

Statistiques de consultation

Publications les plus consultéesStatistiques par paysAuteurs les plus consultés

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales