Relevance of using a compressive preload in the cervical spine : an experimental and numerical simulating investigation
Article dans une revue avec comité de lecture
Auteur
Date
2015Journal
European Journal of Orthopaedic Surgery & TraumatologyRésumé
Simulating compressive action of muscles, a follower load attends to reproduce a more physiological biomechanical behaviour of the cervical spine. Only few experimental studies reported its influence on kinematics and intradiscal pressure in the cervical spine. STUDY DESIGN: In vitro human cadaveric and numerical simulating evaluation of a compressive preload in the cervical spine. OBJECTIVES: To analyse the influence of a compressive follower preload on the biomechanical behaviour of the cervical spine. METHODS: The present study was divided into two parts: part 1: in vitro investigation; part 2: numerical simulating analysis. Part 1: Twelve human cadaveric spines from C2 to T2 were evaluated intact and after application of a 50-N follower load. All tests were performed under load control by applying pure moments loading of 2 Nm in flexion/extension (FE), axial rotation (AR) and lateral bending (LB). Three-dimensional displacements were measured using an optoelectronic system, and intradiscal pressures were measured at two levels. Part 2: Using a 3D finite element model, we evaluated the influence of a 50- and 100-N compressive preload on intradiscal loads, facets forces and ranges of motion. Different positions of the follower load along the anteroposterior axis (±5 mm) were also simulated. RESULTS: Part 1: Mean variation of cervical lordosis was 5° ± 3°. The ROM slightly increased in FE, whereas it consistently decreased in AR and LB. Coupled lateral bending during AR was also reduced. Increase in hysteresis was observed on load-displacement curves only for AR and LB. Intradiscal pressures increased, but the aspect of load-pressure curves was altered in AR and LB. Part 2: Using the FE model, only minimal changes in ROM were noted following the simulation of a 50-N compressive load for the three loading conditions. Compared to intact condition, <10% variation was observed with regard to the different magnitude and positioning simulated. Intradiscal loads and facets forces were systematically increased by applying compressive preload. CONCLUSIONS: Although the follower load represents an attractive option to apply compressive preload during experimental tests, we found that this method could affect the native biomechanical behaviour of spine specimen depending on which movement was considered. Only minimal effects were observed in FE, whereas significant changes in kinematics and intradiscal pressures were observed for AR and LB.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureLAZENNEC, Jean-Yves; EVEN, Julien; SKALLI, Wafa; RAKOVER, Jean-Patrick; BRUSSON, Adrien; ROUSSEAU, Marc-Antoine (Elsevier BV, 2014)Background context: Surgical treatment of degenerative disc disease remains a controversial subject. Lumbar fusion has been associated with a potential risk of segmental junctional disease and sagittal balance misalignment. ...
-
A new quasi-invariant parameter characterizing the postural alignment of young asymptomatic adults Article dans une revue avec comité de lectureAMABILE, Célia; LAFAGE, Virginie; BARREY, Cédric; VITAL, Jean-Marc; SKALLI, Wafa; PILLET, Helene (Springer Verlag, 2016)Purpose Our study aims to describe the postural alignment of young asymptomatic subjects from head to feet from bi-planar standing full-body X-rays, providing database to compare to aging adults. Novelty resides in the ...
-
Article dans une revue avec comité de lectureLAZENNEC, Jean-Yves; BRUSSON, Adrien; ROUSSEAU, Marc-Antoine; ROBBINS, Christopher B.; POUR, Aidin Eslam (Elsevier, 2016)BACKGROUND: This study compared 2- and 3-dimensional (2D and 3D) radiographic measurements of anatomical and functional leg length and knee coronal and sagittal alignments and correlated these measurements with patients' ...
-
Article dans une revue avec comité de lectureLAZENNEC, Jean-Yves; BRUSSON, Adrien; FOLINAIS, Dominique; ROUSSEAU, Marc-Antoine; POUR, Aidin Eslam (Springer Verlag, 2015)Purpose Accurate evaluation of femoral offset is difficult with conventional anteroposterior (AP) X-rays. The EOS imaging system is a system that makes the acquisition of simultaneous and orthogonal AP and lateral images ...
-
Article dans une revue avec comité de lectureLAZENNEC, Jean-Yves; FOLINAIS, Dominique; BENDAYA, Samy; ROUSSEAU, Marc-Antoine; POUR, Aidin Eslam (Springer-Verlag, 2016)Lumbar stenosis is frequently observed and treated by spine surgeons. The extent of neurological decompression and the potential spinal fixation are the basic concerns when surgery is planned. But this segmented approach ...