Virtual current vector‐based method for inverter open‐switch and open‐phase fault diagnosis in multiphase permanent magnet synchronous motor drives

Article dans une revue avec comité de lecture
Author
TRABELSI, Mohamed
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
ccSEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]

URI
http://hdl.handle.net/10985/20660
Date
2021
Journal
IET Electric Power Applications

Abstract

Multiphase permanent magnet synchronous motor (PMSM) drives. First defined are adequate variables called virtual current vectors. The projection of the zero‐sequence current component on these variables was used to define two simple fault indices. High sensitivity to fault is thus induced but with a good robustness to transient states and variation of machine parameters. The mathematical development of the proposed method is provided and supported by experimental tests conducted on two prototypes of multiphase machines in the laboratory: sinusoidal and bi‐harmonic PMSMs. The experimental results confirm the effectiveness and the robustness of the proposed method and its capability to detect the single and multiple open‐switches and open‐phase faults in the electric drive.

Files in this item

Name:
L2EP_EPA_2021_TRABELSI.pdf
Size:
5.588Mb
Format:
PDF
View/Open

Collections

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Related items

Showing items related by title, author, creator and subject.

  • Real-Time Switches Fault Diagnosis Based on Typical Operating Characteristics of Five-Phase Permanent Magnetic Synchronous Machines 
    Article dans une revue avec comité de lecture
    TRABELSI, Mohamed; ccSEMAIL, Eric; ccNGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)
    A novel centroid-based diagnostic method of the power switches in five-leg Voltage Source Inverter (VSI) is proposed in this paper. Using a vectorial multi-machine description, a five-phase drive presenting an opened switch ...
  • Open Switch Fault Effects Analysis (OSFEA) in Five Phase PMSM Designed for Aerospace Application 
    Communication avec acte
    TRABELSI, Mohamed; ccSEMAIL, Eric; MEINGUET, Fabien; ccNGUYEN, Ngac Ky (IEEE, 2016)
    This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For these demanding applications, ...
  • Open-Switch and Open-Phase Real Time FDI Process for Multiphase PM Synchronous Motors 
    Communication avec acte
    TRABELSI, Mohamed; MEINGUET, Fabien; ccSEMAIL, Eric; ccNGUYEN, Ngac Ky (ISIE Conference, 2016)
    This paper deals with the real time Fault Detection and Identification (FDI) process of inverter Open Switch Fault (OSF) and Open Phase Fault (OPF) in five-phase PMSM designed for aerospace applications in which the electric ...
  • Low Speed Sensorless Control of Non-Salient Poles Multiphase PMSM 
    Communication avec acte
    TORRES GUZMAN, Diana Angelica; TRABELSI, Mohamed; ccSEMAIL, Eric; ccNGUYEN, Ngac Ky (IEEE, 2019)
    This article presents the development of an algorithm which can be used at standstill and low speed for sensorless control of a five-phase Permanent Manget Synchronous Machines (PMSM) with non-salient poles. The estimation ...
  • Homopolar Current’s Copper Losses Analysis for Different Modulations in Open-End Winding Five-Phase drives 
    Communication avec acte
    DOS SANTOS MORAES, Tiago José; TRABELSI, Mohamed; ZAHR, Hussein; ccSEMAIL, Eric (IEEE, 2018)
    This paper analyses the copper losses due to the homopolar current of a five-phase open-end winding machine supplied by a 10-leg inverter and a single DC voltage source. This topology can have non-null high frequency ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales