Virtual current vector‐based method for inverter open‐switch and open‐phase fault diagnosis in multiphase permanent magnet synchronous motor drives
Article dans une revue avec comité de lecture
Abstract
Multiphase permanent magnet synchronous motor (PMSM) drives. First defined are adequate variables called virtual current vectors. The projection of the zero‐sequence current component on these variables was used to define two simple fault indices. High sensitivity to fault is thus induced but with a good robustness to transient states and variation of machine parameters. The mathematical development of the proposed method is provided and supported by experimental tests conducted on two prototypes of multiphase machines in the laboratory: sinusoidal and bi‐harmonic PMSMs. The experimental results confirm the effectiveness and the robustness of the proposed method and its capability to detect the single and multiple open‐switches and open‐phase faults in the electric drive.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureTRABELSI, Mohamed;
SEMAIL, Eric;
NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)
A novel centroid-based diagnostic method of the power switches in five-leg Voltage Source Inverter (VSI) is proposed in this paper. Using a vectorial multi-machine description, a five-phase drive presenting an opened switch ... -
Communication avec acteThis paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For these demanding applications, ...
-
Communication avec acteThis paper deals with the real time Fault Detection and Identification (FDI) process of inverter Open Switch Fault (OSF) and Open Phase Fault (OPF) in five-phase PMSM designed for aerospace applications in which the electric ...
-
Communication avec acteThis article presents the development of an algorithm which can be used at standstill and low speed for sensorless control of a five-phase Permanent Manget Synchronous Machines (PMSM) with non-salient poles. The estimation ...
-