The reduction of operational amplifier electrical outputs to improve piezoelectric shunts with negative capacitance
Article dans une revue avec comité de lecture
Author
Date
2021-08Journal
Journal of Sound and VibrationAbstract
One way to enhance the performance of vibration control with piezoelectric shunt is to use a negative capacitance in the shunt circuit. This component is very effective and pro- vides good results in terms of attenuation improvement without significantly increasing the complexity of the shunt network. However, negative capacitances are built using oper- ational amplifiers and, in some applications, the risk of saturation of the outputs of the operational amplifier exists. This constitutes a non-negligible aspect since it leads to a non-proper functioning of the control system which significantly deteriorates the control performance or even triggers instability phenomena. In light of this limitation, this paper proposes strategies to decrease the outputs of the operational amplifier in order to reduce the risk of saturation acting just on the values of the circuit components, without worsen- ing the attenuation performance. However, when the achievable reduction is not sufficient, it is also possible to act on other components accepting a deterioration of the attenuation performance. Guidelines are provided for properly choosing the best shunt circuit configu- ration accounting for both the extent of the operational amplifier outputs and the control performance. The paper also evidences that the mechanical part of the system cannot be neglected in the analysis when assessing the operational amplifier outputs. Furthermore, two different circuit types used to build the negative capacitance are compared in terms of output requirements. This analysis shows that there is no circuit always less demanding than the other and that the choice of the circuit is not always straightforward. Therefore, a multi-degree of freedom model is presented, which is essential to understand which con- figuration of the negative capacitance has to be used in a given engineering application. All the presented outcomes are validated through an experimental campaign.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Communication avec acteThis article proposes a new layout of electrical network based on two negative capacitance circuits, aimed at increasing the performances of a traditional resistive piezoelectric shunt for structural vibration reduction. ...
-
Article dans une revue avec comité de lectureBERARDENGO, Marta; THOMAS, Olivier; MANZONI, Stefano; GIRAUD-AUDINE, Christophe (SAGE Publications, 2016)This paper deals with piezoelectric shunt damping enhanced with negative capacitances. A novel electrical circuit layout is addressed, based on the use of two negative capacitances. It is shown that the shunt performances, ...
-
Article dans une revue avec comité de lectureBERARDENGO, Marta; THOMAS, Olivier; MANZONI, Stefano; GIRAUD-AUDINE, Christophe (IOP Publishing, 2016)This paper deals with vibration control by means of piezoelectric patches shunted with electrical impedances made up by a resistance and a negative capacitance. The paper analyses most of the possible layouts by which a ...
-
Article dans une revue avec comité de lectureThis article addresses piezoelectric shunt damping through a resonant shunt associated with negative capacitances. The main objective of this article is to provide guidelines for choosing the best electrical circuit layout ...
-
Article dans une revue avec comité de lectureThis paper addresses the vibration attenuation provided by the resonant piezoelectric shunt enhanced by means of negative capacitances. The shunt impedance is composed by one or two negative capacitances, a resistance and ...