Internal fatigue crack propagation in a Ti-6Al-4V alloy: An in situ study
Article dans une revue avec comité de lecture
Date
2023-03Journal
International Journal of FatigueRésumé
Fatigue specimens of a Ti-6Al-4V alloy containing internal artificial defects with controlled and reproducible size and shape have been produced. These defects systematically led to the initiation of a fatigue crack which propagation has been monitored in situ by synchrotron X-ray tomography during R=0.1 uniaxial fatigue tests at 20 Hz. The crack growth curves of the internal cracks have been obtained for 6 samples. Ex situ fatigue tests have been performed on samples submitted to a supplementary heat treatment or containing a defect put into contact with air. The results obtained tend to support the fact that internal fatigue cracks grow from the notch in a vacuum environment. On the fracture surfaces of samples containing an artificial defect not connected to air, two regions have been observed. They correspond to the Rough Area and the Fish Eye regions observed for internal cracks initiated from natural defects. The transition between those two regions takes place when the plastic radius size is equivalent to the grain size.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureMESSAGER, Alexandre; JUNET, Arnaud; PALIN-LUC, Thierry; BUFFIERE, Jean-Yves; EL MAY, Mohamed; GAILLARD, Yves; KING, Andrew; BONNIN, Anne; NADOT, Yves; RANC, Nicolas; SAINTIER, Nicolas (Wiley-Blackwell, 2020)This work presents a new ultrasonic fatigue testing device for studying the initiation and propagation mechanisms of internal microstructurally short fatigue cracks using in situ synchrotron tomography. Its principle is ...
-
Article dans une revue avec comité de lectureRANC, Nicolas; MESSAGER, Alexandre; JUNET, Arnaud; PALIN-LUC, Thierry; BUFFIERE, Jean-Yves; SAINTIER, Nicolas; ELMAY, Wafa; MANCINI, L.; KING, Andrew; NADOT, Yves (Elsevier, 2022-09)Very high cycle fatigue fracture is often associated with internal crack propagation and one major problem to study the initiation and the propagation of this internal crack is to detect its initiation and quantify its ...
-
Article dans une revue avec comité de lectureJUNET, Arnaud; MESSAGER, Alexandre; BOULNAT, Xavier; WECK, Arnaud; BOLLER, Elodie; HELFEN, Lukas; BUFFIERE, Jean-Yves (Elsevier, 2019)Fatigue specimens designed with controlled internal defects were obtained by diffusion bonding of Ti-6Al-4V sheets containing femtosecond laser drilled notches. Crack initiation from the internal defect occurred systematically. ...
-
Communication avec acteThis issue of Fatigue and Fracture of Engineering Materials and Structures contains a collection of manuscripts presented at the Second International Symposium on Fatigue Design and Material Defects (FDMD II) held in Paris, ...
-
Environment effect on internal fatigue crack propagation studied with in-situ X-ray microtomography Article dans une revue avec comité de lectureHEBRARD, Louis; BUFFIERE, Jean-Yves; PALIN-LUC, Thierry; RANC, Nicolas; MAJKUT, Marta; KING, Andrew; WECK, Arnaud (2023)In the present study, physically short fatigue cracks initiated from an artificial internal notch under vacuum conditions are observed in smooth specimens made of titanium alloy. The crack initiated from such a notch is ...