Flip-chip technology at room temperature: A new design of microtube-based interconnect for improved mechanical and electrical properties
Article dans une revue avec comité de lecture
Date
2024-10Journal
Sensors and Actuators: A. PhysicalRésumé
Flip-chip assembly of photonic components can be achieved at room temperature by using 10 μm pitch interconnects made of metallised oxide microtubes inserted into ductile reception pads. In order to reduce the electrical resistance of interconnects and the assembly force required, interconnect design in regard to geometry and materials used are optimised through electrical and mechanical finite elements (FEM) simulations. To reduce electrical resistance, one may increase the metallisation thickness or microtube inner diameter. To minimise the assembly force, reducing the reception pad diameter is recommended. Experiments on silicon (Si) test vehicles are conducted to validate these predictions; they indicate that there is no short circuit, with an effectiveness of 100 %. This is achieved first through the assembly of Al-0.5 %wCu metallised oxide microtubes into Al-0.5 %wCu
reception pads, using a force less than 10 mN/interconnect and proved to have a resistance of 230 mΩ. Second, with gold (Au) metallised oxide microtubes in indium (In) pads assembled with a force less than 0.7 mN/ interconnect. Last interconnects have a resistance of 670 mΩ/interconnect and can still be reduced to 500 mΩ by 2 h annealing at 100 ◦C.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureNanoporous membranes are used for the elaboration of implantable medical devices. In order to guaranty their integrity after implantation in a patient body, it is necessary to characterize the microstructure and the ...
-
Article dans une revue avec comité de lectureThe mechanical behaviour of a CdHgTe-based infrared detector was evaluated after processing at several temperatures to determine the impact of thermomechanical loading on residual stress and reliability. The architecture ...
-
Conférence invitéeA specific in-situ tensile device has been set up in an X-Ray diffractometer. Stress can be measured at low temperature during loading in the baintic steel and in the ferritic phase. A two-scale modeling has been proposed ...
-
Micromachine d'essais mécaniques de type traction et compression ayant une accessibilité optimisée BrevetBOMONT, Olivier; WARY, Marc; BIANCHIN, Jeremy; SIMON, Lionel; BOEHM, Daniel; HECKER, Jean-Michel; PEIFFERT, Xavier; PESCI, Raphaël (2015)L'invention concerne une micromachine de traction destinée à être utilisée dans une enceinte de microscope électronique à balayage ou avec un appareil de diffraction, comportant deux mors (1) portés par deux supports, ...
-
Article dans une revue avec comité de lectureINAL, Karim; LEBRUN, Jean-Lou; DIARD, Olivier; MASSON, Renaud; PESCI, Raphaël (Wiley-Blackwell, 2006)Stress analyses by X-ray diffraction are performed on a cast duplex (32% ferrite) stainless steel elbow and a bainitic (95% ferrite) pressure vessel steel. During an in situ tensile test, micrographic observations are made ...