The Measurement of Spatiotemporal Parameters in Running at Different Velocities: A Comparison Between a GPS Unit and an Infrared Mat
Article dans une revue avec comité de lecture
Date
2024-12-20Journal
Methods and ProtocolsAbstract
The accurate measurement of spatiotemporal parameters, such as step length and step frequency, is crucial for analyzing running and sprinting performance. Traditional methods like video analysis and force platforms are either time consuming or limited in scope, prompting the need for more efficient technologies. This study evaluates the effectiveness of a commercial Global Positioning System (GPS) unit integrated with an Inertial Measurement Unit (IMU) in capturing these parameters during sprints at varying velocities. Five experienced male runners performed six 40 m sprints at three velocity conditions (S: Slow, M: Medium, F: Fast) while equipped with a GPS-IMU system and an optical system as the gold standard reference. A total of 398 steps were analyzed for this study. Step frequency, step length and step velocity were extracted and compared using statistical methods, including the coefficient of determination (r2) and root mean square error (RMSE). Results indicated a very large agreement between the embedded system and the reference system, for the step frequency (r2 = 0.92, RMSE = 0.14 Hz), for the step length (r2 = 0.91, RMSE = 0.07 m) and the step velocity (r2 = 0.99, RMSE = 0.17 m/s). The GPS-IMU system accurately measured spatiotemporal parameters across different running velocities, demonstrating low relative errors and high precision. This study demonstrates that GPS-IMU systems can provide comprehensive spatiotemporal data, making them valuable for both training and competition. The integration of these technologies offers practical benefits, helping coaches better understand and enhance running performance. Future improvements in sample rate acquisition GPS-IMU technology could further increase measurement accuracy and expand its application in elite sports.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureBOURGAIN, Maxime; PROVOT, Thomas; BONNET, Xavier (Tempus Publications, 2020)This paper presents the development of a prosthetic foot designed by engineering-school students. A complete workflow from needs definition to the production and testing was performed. The standards for adults were adapted ...
-
Communication avec acteBOURGAIN, Maxime; PROVOT, Thomas; SAURET, Christophe; VALDES-TAMAYO, Laura; ROUILLON, Olivier; THOREUX, Patricia;
ROUCH, Philippe (Informa UK Limited, 2020)
Study of th intra-individual variability of the motor moment during the golf swing. It highlighted the variability induced by horizontal ground reaction forces which are rarely taken into account in field. -
Article dans une revue avec comité de lectureSIERRA M, Sergio D.; MUNERA, Marcela; PROVOT, Thomas; BOURGAIN, Maxime; CIFUENTES, Carlos A. (MDPI AG, 2021)Smart walkers are commonly used as potential gait assistance devices, to provide physical and cognitive assistance within rehabilitation and clinical scenarios. To understand such rehabilitation processes, several biomechanical ...
-
Article dans une revue avec comité de lecturePROVOT, Thomas; CHIEMENTIN, Xavier; BOLAERS, Fabrice; MURER, Sebastien (Taylor and Francis Ltd, 2021-11)Amplified by the development of new technologies, the interest in personal performance has been growing over the last years. Acceleration has proved to be an easy variable to collect, and was addressed in several works. ...
-
Article dans une revue avec comité de lecturePROVOT, Thomas; CHIEMENTIN, Xavier; BOLAERS, Fabrice; MUNERA, Marcela (Informa Uk Limited, 2019-01)Defining relationships between running mechanisms and fatigue can be a major asset for optimising training. This article proposes a biomechanical model of time to exhaustion according to indicators derived from accelerometry ...