Flux-Weakening Strategies for a Five-Phase PM Synchronous Machine

Communication avec acte
Auteur
LU, Li
KOBYLANSKI, Luc
ccSEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
ccKESTELYN, Xavier

URI
http://hdl.handle.net/10985/6742
Date
2011

Résumé

In order to get a low cost mild hybrid system, a global objective is to keep the actual thermal engine architecture. As consequence, the current clawpole synchronous automotive generator must be replaced by a new more powerful electrical machine but with the same large speed range [0 -18000 rpm]. In the project, a power of 15 kW and a DC bus voltage of 60V have been chosen to provide a regenerative breaking at minimum cost. With this payload (250A for the DC bus current), a five-phase machine appears to be interesting because MOSFET transistors of the voltage source inverter (VSI) have not to be used in parallel configuration (only two rated 150A transistors per leg for the VSI). As the speed range is large, a flux weakening must be applied. As the five-phase drives have more degrees of freedom than three-phase ones, different flux weakening strategies can be considered. The aim of this paper is to compare one of them.

Fichier(s) constituant cette publication

Nom:
Flux-Weakening Strategies for a ...
Taille:
822.0Ko
Format:
PDF
Voir/Ouvrir

Cette publication figure dans le(s) laboratoire(s) suivant(s)

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Documents liés

Visualiser des documents liés par titre, auteur, créateur et sujet.

  • Computation of Optimal Current References for Flux-weakening of Multi-Phase Synchronous Machines 
    Communication avec acte
    LU, Li; ASLAN, Bassel; KOBYLANSKI, Luc; SANDULESCU, Paul; MEINGUET, Fabien; ccSEMAIL, Eric; ccKESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2012)
    Multi-phase synchronous machines are more and more used in specific applications where high power density, low bus voltage, wide speed range and fault-tolerant capabilities are required. Due to the high number of degrees ...
  • Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives 
    Communication avec acte
    MEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; LU, Li; ccSEMAIL, Eric; ccKESTELYN, Xavier; NGUYEN, Ngac Ky (IEEE - Institute of Electrical and Electronics Engineers, 2012)
    A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based ...
  • Inversion-based control of electromechanical systems using causal graphical descriptions 
    Communication avec acte
    BARRE, Pierre-Jean; BOUSCAYROL, Alain; DELARUE, Philippe; DUMETZ, Eric; GIRAUD, Frédéric; HAUTIER, Jean-Paul; LEMAIRE-SEMAIL, Betty; ccSEMAIL, Eric; ccKESTELYN, Xavier (IEEE, 2006)
    Causal Ordering Graph and Energetic Macroscopic Representation are graphical descriptions to model electromechanical systems using integral causality. Inversion rules have been defined in order to deduce control structure ...
  • Modélisation causale pour la commande auto adaptée de machines alternatives triphasées en mode dégradé 
    Article dans une revue avec comité de lecture
    CREVITS, Yvan; LEMAIRE-SEMAIL, Betty; ccSEMAIL, Eric; ccKESTELYN, Xavier (Lavoisier, 2010)
    After a short historic of the multiphase machines and the state of the art of their open-circuited phase operation, this paper deals with a decoupled three-phase motor drive using a synchronous or induction machine. The ...
  • Fault Tolerant Multiphase Electrical Drives: The Impact of Design 
    Article dans une revue avec comité de lecture
    LOCMENT, Fabrice; ccSEMAIL, Eric; ccKESTELYN, Xavier (EDP Sciences, 2008)
    This paper deals with fault tolerant multiphase electrical drives. The quality of the torque of a vector-controlled Permanent Magnet (PM) Synchronous Machine supplied by a multi-leg Voltage Source Inverter (VSI) is examined ...

Parcourir

Tout SAMLaboratoiresAuteursDates de publicationCampus/InstitutsCe LaboratoireAuteursDates de publicationCampus/Instituts

Lettre Diffuser la Science

Dernière lettreVoir plus

Statistiques de consultation

Publications les plus consultéesStatistiques par paysAuteurs les plus consultés

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales