Influence of Rotor Structure and Number of Phases on First and Second Order Characteristics of TOYOTA PRIUS Electrical Machine Type

Communication avec acte
Author
ASLAN, Bassel
KORECKI, Julien
VIGIER, Thimoté
ccSEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]

URI
http://hdl.handle.net/10985/6753
Date
2011

Abstract

This paper investigates the influence of the rotor structure on torque and Flux weakening region of V-shape IPM machine from TOYOTA PRIUS type, more specifically, keeping always the same magnet volume, we study the effect of the open angle between the two magnet segments of each V-shape pole on the machine performance. Moreover, in order to examine the impact of phase number on the machine characteristics, PRIUS structure is transformed into 5-phase machine of the same type and dimensions. As well, an optimization procedure is carried out to determine the optimal open angle according to main characteristics. The previous investigation is done by using a free Finite Elements Methods (FEM) program coupled with another optimization program. Using this obtained methodology the study analyzes for 3-phase and 5-phase machine the average and pulsation of torque, cogging torque, phase back-EMF, constant power operating capability.

Files in this item

Name:
ever11ABJKES.pdf
Size:
447.4Kb
Format:
PDF
Description:
Congres vfinale
View/Open

Collections

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Related items

Showing items related by title, author, creator and subject.

  • Influence of Rotor Structure and Number of Phases on Torque and Flux Weakening Characteristics of V-Shape Interior PM Electrical Machine 
    Article dans une revue sans comité de lecture
    ASLAN, Bassel; KORECKI, Julien; VIGIER, Thimoté; ccSEMAIL, Eric (David publishing compagny, 2012)
    This paper investigates the influence of the rotor structure on torque and flux weakening region of V-shape IPM (interior permanent magnet) machine from TOYOTA PRIUS type. More specifically, always keeping the same magnet ...
  • Slot/pole Combinations Choice for Concentrated Multiphase Machines dedicated to Mild-Hybrid Applications 
    Communication avec acte
    ASLAN, Bassel; KORECKI, Julien; LEGRANGER, Jerome; ccSEMAIL, Eric (IEEE, 2011)
    This paper presents multiphase permanent magnet machines with concentrated non-overlapped winding as a good candidate for automotive low voltage mild-hybrid applications. These machines often require a trade-off between ...
  • HIGH SPEED FUNCTIONALITY OPTIMIZATION OF FIVE-PHASE PM MACHINE USING 3RD HARMONIC CURRENT 
    Article dans une revue avec comité de lecture
    GONG, Jinlin; ASLAN, Bassel; GILLON, Frédéric; ccSEMAIL, Eric (Emerald, 2014)
    Some surrogate-assisted optimization techniques are applied in order to improve the performances of a 5-phase Permanent Magnet (PM) machine in the context of a complex model requiring computation time. An optimal control ...
  • Maximum Torque Per Ampere Strategy for a Biharmonic Five-phase Synchronous Machine 
    Communication avec acte
    ZAHR, Hussein; ASLAN, Bassel; ccSEMAIL, Eric; ccSCUILLER, Franck (IEEE, 2016)
    The paper studies the impact of first and third current-harmonic repartition in a five-phase Permanent Magnet machine whose Electromotive Forces (emfs) have first and third harmonics of the same amplitude. With a five-phase ...
  • Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives 
    Communication avec acte
    MEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; LU, Li; ccSEMAIL, Eric; ccKESTELYN, Xavier; ccNGUYEN, Ngac Ky (IEEE - Institute of Electrical and Electronics Engineers, 2012)
    A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales