Numerical Simulation of Flow Field Formed in Water Pump-Sump
Communication avec acte
Date
2008Résumé
Two fundamental types of flow problems besetting water intakes are swirling flow problems in the pump sump and sediment problems at entrance or within intakes. Both problems reduce intake performance and lead to increased plant operating costs. Experiments were conducted in a laboratory** in order to select best positions of the suction pipe of a water-intake sump. These experiments show qualitative results concerning flow disturbances in the pump-intake related to sump geometries and position of the pump intake. The purpose of the paper is to reproduce the flow pattern and confirm the geometrical parameter influences of the flow behavior in such a pump. The numerical model solves the Reynolds averaged Navier-Stokes (RANS) equations with a near- wall turbulence model. In the validation of this numerical model, emphasis was placed on the prediction of the number, location, size and strength of the various types of vortices. The paper mainly focuses first, on mesh geometry turbulence model, closures and boundary conditions. Secondly, a comparison of different flow patterns for several intake locations in the sump will be presented.
Fichier(s) constituant cette publication
- Nom:
- issa2_AIRH_24th.pdf
- Taille:
- 889.1Ko
- Format:
- Description:
- document article principal
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteNumerous different experimental and numerical methods have been developed and are already improved in order to get rather good flow descriptions inside pump components. These calculations are generally realized assuming ...
-
Two-phase numerical study of the flow field formed in water pump sump: influence of air entrainment Article dans une revue avec comité de lectureBAYEUL-LAINÉ, Annie-Claude; SIMONET, Sophie; BOIS, Gérard; ISSA, Abir (IOP - Institute of Physics, 2012)In a pump sump it is imperative that the amount of non-homogenous flow and entrained air be kept to a minimum. Free air-core vortex occurring at a water-intake pipe is an important problem encountered in hydraulic engineering. ...
-
Article dans une revue avec comité de lectureThere are several important considerations in the design of a suction supply sump. It is imperative that the amount of turbulence and entrained air be kept to a minimum. Free aircore vortex occurring at a water-intake pipe ...
-
Communication avec acteISSA, Abir; BOIS, Gérard; BAYEUL-LAINÉ, Annie-Claude (CMFF - Conference on Modelling Fluid Flow, 2009)Water for irrigation, domestic and industrial supply as well for some power generation is normally drawn directly from rivers or from reservoir through sumps. The flow at the pump section sump may have large effects on the ...
-
Article dans une revue avec comité de lectureDUPONT, Patrick; CAVAZZINI, Giovanna; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (2013)The paper presents analysis of the performance and the internal flow behaviour in the vaned diffusor of a radial flow pump using PIV (Particle Image Velocimetry) and pressure probe traverses. PIV measurements have already ...