Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives
Communication avec acte
Résumé
This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit and current sensor outage. The method is based on the monitoring of the abc currents with phase-locked loops and the ‘CUSUM’ algorithm for the decision system. The impact of the considered faults is examined: first, in case there is no modification of the control and then in case a control reconfiguration is performed taking into account the fault diagnosis. Closed-loop operation is performed before, during and after the fault. Experimental results show that the latter case allows maintaining the drive in safe operation.
Fichier(s) constituant cette publication
- Nom:
- ISIE_full_paper_Meinguet_v4.pdf
- Taille:
- 564.0Ko
- Format:
- Description:
- document article principal
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; MOLLET, Yves; GYSELINCK, Johan;
SEMAIL, Eric;
KESTELYN, Xavier (Institution of Engineering and Technology, 2014)
This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the ... -
Flux-weakening operation of open-end winding drive integrating a cost effective high-power charger Article dans une revue avec comité de lectureIn this paper, a three-phase drive with a six-leg Voltage Source Inverter (VSI) and an open-end winding Interior Permanent Magnet Synchronous Machine (IPMSM) designed for the traction of an electric vehicle is studied in ...
-
Article dans une revue avec comité de lectureSANDULESCU, Paul; MEINGUET, Fabien; BRUYERE, Antoine;
SEMAIL, Eric;
KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2014)
This paper presents and compares control strategies for three-phase open-end winding drives operating in the flux-weakening region. A six-leg inverter with a single dc-link is associated with the machine in order to use a ... -
Communication avec acteMulti-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SANDULESCU, Paul;
SEMAIL, Eric;
KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2013)
A general method for fault detection and isolation is proposed and applied to inverter faults in drives of electric vehicles. This method is based on a change-detection algorithm, which allows multiple fault indices to be ...