• français
    • English
    English
  • Ouvrir une session
Aide
Voir le document 
  •   Accueil de SAM
  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille
  • Voir le document
  • Accueil de SAM
  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille
  • Voir le document
JavaScript is disabled for your browser. Some features of this site may not work without it.

A change-detection algorithm for short-circuit fault detection in closed-loop AC drives

Article dans une revue avec comité de lecture
Auteur
MEINGUET, Fabien
MOLLET, Yves
GYSELINCK, Johan
ccSEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
ccKESTELYN, Xavier

URI
http://hdl.handle.net/10985/7340
DOI
10.1049/iet-epa.2012.0316
Date
2014
Journal
IET Electric Power Applications

Résumé

This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the voltage. Therefore, an appropriate diagnostic index is proposed, which is derived from the positive- and negative-sequences of the voltage references. These sequences are obtained in the time domain via adaptive filters, which require only a few calculations. To increase the sensitivity to the fault, the algorithm is only applied to a part of the voltage references, i.e. the output of the proportional-integral controllers. Further, the cumulative-sum algorithm is introduced to cope with changes of small magnitudes. This algorithm allows a change of a fault index to be detected and can be used as a decision system. The resulting fault detection scheme is computationally cheap and can be embedded in the control unit. Simulations and experimental results validate the proposed method in steady state and the performances under non-stationary operating conditions are also investigated.

Fichier(s) constituant cette publication

Nom:
L2EP_IET Power Applications_20 ...
Taille:
1.140Mo
Format:
PDF
Voir/Ouvrir

Cette publication figure dans le(s) laboratoire(s) suivant(s)

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Documents liés

Visualiser des documents liés par titre, auteur, créateur et sujet.

  • Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives 
    Communication avec acte
    MEINGUET, Fabien; GYSELINCK, Johan; ccSEMAIL, Eric; ccKESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2011)
    This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit ...
  • Enhanced Torque Control of a PMSM Supplied by a Four-Leg Voltage Source Inverter Using the Third Harmonic 
    Communication avec acte
    MEINGUET, Fabien; GYSELINCK, Johan; ccSEMAIL, Eric (IEEE, 2008)
    This paper investigates an electrical drive composed of a four-leg voltage source inverter and a three-phase starconnected surface permanent magnet synchronous machine with concentrated windings. The inverter fourth leg ...
  • An On-line Method for Stator Fault Detection in Multi-phase PMSM Drives 
    Communication avec acte
    MEINGUET, Fabien; GYSELINCK, Johan; ccSEMAIL, Eric (IEEE - Institute of Electrical and Electronics Engineers, 2010)
    This paper deals with an on-line fault detection method for multi-phase PMSM drives. The method is based on the detection of the stator current positive- and negative sequence fundamental components expressed in the ...
  • Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Short-Circuit Inverter Fault 
    Article dans une revue avec comité de lecture
    MEINGUET, Fabien; ccSEMAIL, Eric; ccKESTELYN, Xavier; ccNGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)
    Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...
  • Flux-weakening operation of open-end winding drive integrating a cost effective high-power charger 
    Article dans une revue avec comité de lecture
    SANDULESCU, Paul; MEINGUET, Fabien; BRUYERE, Antoine; ccSEMAIL, Eric; ccKESTELYN, Xavier (IEEE, 2013)
    In this paper, a three-phase drive with a six-leg Voltage Source Inverter (VSI) and an open-end winding Interior Permanent Magnet Synchronous Machine (IPMSM) designed for the traction of an electric vehicle is studied in ...

Parcourir

Tout SAMLaboratoiresAuteursDates de publicationCampus/InstitutsCe LaboratoireAuteursDates de publicationCampus/Instituts