Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Inverter Faults
Communication avec acte
Date
2013Résumé
Multi-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of an open-end five-phase drive, i.e. a multi-phase machine fed with a dual-inverter supply. Open-circuit faults and inverter switch short-circuit faults are considered and handled with various degrees of reconfiguration. Theoretical developments and experimental results validate the proposed strategies.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteMEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; LU, Li; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (IEEE - Institute of Electrical and Electronics Engineers, 2012)A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based ...
-
Communication avec acteMEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (EPE Conference, 2013)This paper presents a specific control strategy of double-ended inverter system for wide-speed range of open-winding five phase PM machines. Different virtual winding configurations (star, pentagon, pentacle and bipolar) ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...
-
BrevetBRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; SEMAIL, Eric; KESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...
-
Article dans une revue avec comité de lectureSANDULESCU, Paul; MEINGUET, Fabien; BRUYERE, Antoine; SEMAIL, Eric; KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2014)This paper presents and compares control strategies for three-phase open-end winding drives operating in the flux-weakening region. A six-leg inverter with a single dc-link is associated with the machine in order to use a ...