Comparisons Between Numerical Calculations and Measurements in the Vaned Diffusor of SHF Impeller
Article dans une revue avec comité de lecture
Date
2013Journal
Journal of Drainage and Irrigation Machinery EngineeringRésumé
The paper presents analysis of the performance and the internal flow behaviour in the vaned diffusor of a radial flow pump using PIV (Particle Image Velocimetry) and pressure probe traverses. PIV measurements have already been performed at mid height inside one diffusor channel passage for a given speed of rotation and various mass flow rates. These results have been already presented in several previous communications. New experiments have been performed using a 3 holes pressure probe traverses from hub to shroud diffusor width at different radial locations between the two diffusor geometrical throats. Numerical simulations are also realized with the commercial codes Star CCM+ 7.02.011 and CFX. Frozen rotor and fully unsteady calculations of the whole pump have been performed. Comparisons between numerical results, previous experimental PIV results and new probe traverses one’s are presented and discussed for one mass flow rate. In this respect, a first attempt to take into account fluid leakages between the rotating and fixed part of the pump has been checked since it may affect the real flow structure inside the diffuser
Fichier(s) constituant cette publication
- Nom:
- 2014-drainage_v4.pdf
- Taille:
- 1.252Mo
- Format:
- Description:
- article
- Fin d'embargo:
- 2017-11-08
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteDUPONT, Patrick; CAVAZZINI, Giovanna; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (2013)The paper presents the numerical and experimental analysis of performance and internal flow behaviour in the vaned diffuser of a radial flow pump (Fig. 1) using PIV technique (Fig. 2), pressure probe traverses and numerical ...
-
NUMERICAL AND EXPERIMENTAL INVESTIGATIONS IN A VANED DIFFUSER OF SHF IMPELLER: FLUID LEAKAGE EFFECT Communication avec acteDUPONT, Patrick; CAVAZZINI, Giovanna; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (2013)The paper presents the analysis of the performance and the internal flow behaviour in the vaned diffuser of a radial flow pump using PIV technique, pressure probe traverses and numerical simulations. PIV measurements have ...
-
Article dans une revue avec comité de lectureDUPONT, Patrick; CAVAZZINI, Giovanna; PAVESI, Giorgio; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (EDP Sciences, 2015)The paper presents the analysis of the performance and the internal flow behaviour in the vaned diffuser of a radial flow pump using PIV (particles image velocimetry) technique, pressure probe traverses and numerical ...
-
Comparaisons between numerical calculations and measurements in the vaned diffusor of SHF impeller Communication avec acteDUPONT, Patrick; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (2012)The paper presents analysis of the performance and the internal flow behaviour in the vaned diffusor of a radial flow pump using PIV technique and pressure probe traverses. PIV measurements have been performed at mid height ...
-
Communication avec acteCHERDIEU, Patrick; DUPONT, Patrick; ROUSSETTE, Olivier; BOIS, Gérard; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (2013)The aim of this article is to present experimental results obtained on a fan composed of a radial impeller matched with a vaned diffuser. There is no volute downstream to the diffuser. Consequently the diffuser outlet is ...