Analytical Optimal Currents for Multiphase PMSMs Under Fault Conditions and Saturation
Communication avec acte
Date
2014Résumé
An original analytical expression is presented in this paper to obtain optimal currents minimizing the copper losses of a multi-phase Permanent Magnet Synchronous Motor (PMSM) under fault conditions. Based on the existing solutions [i]opt1 (without zero sequence of current constraint) and [i]opt2 (with zero sequence constraint), this new expression of currents [i]opt3 is obtained by means of a geometrical representation and can be applied to open-circuit, defect of current regulation, current saturation and machine phase short-circuit fault. Simulation results are presented to validate the proposed approach.
Fichier(s) constituant cette publication
- Nom:
- IECON_2014_L2EP_ERGE_V4.pdf
- Taille:
- 706.0Ko
- Format:
- Description:
- Communication internationale ...
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteGOMOZOV, Oleg; BUIRE, Jerome; COLAS, Frédéric; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (IEEE, 2015)The optimal control of electrical drives necessitates to take into account current and voltage limits that are imposed by the power electronics and the electrical machines. Let’s cite for example the flux-weakening operation ...
-
Communication avec acteBERMUDEZ GUZMAN, Mario; GOMOZOV, Oleg; SEMAIL, Eric; BARRERO, Federico; KESTELYN, Xavier; NGUYEN, Ngac Ky (ELECTRIMACS, 2017)Multiphase machines have recently gained importance in the research community for their use in applications where high power density, wide speed range and fault-tolerant capabilities are needed. The optimal control of such ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...
-
Article dans une revue avec comité de lectureFALL, Ousmane; CHARPENTIER, Jean-Frederic; LETELLIER, Paul; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (Elsevier, 2016)This paper proposes a novel variable speed control strategy of a particular 5-phase Permanent Magnet Synchronous Generator (PMSG) in healthy and faulty modes by taking into account the constraints on voltages and currents. ...
-
Communication avec acteMEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; LU, Li; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (IEEE - Institute of Electrical and Electronics Engineers, 2012)A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based ...