Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Short-Circuit Inverter Fault
Article dans une revue avec comité de lecture
Date
2016Journal
IEEE Transactions on Industrial ElectronicsRésumé
Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth torque of Permanent Magnet Synchronous Machine (PMSM) if the currents of faulty phases are determined and their values are acceptable. This paper investigates fault-tolerant operations of an open-end fivephase drive, i.e. a multi-phase machine fed with a dual-inverter supply. Inverter switch short-circuit fault is considered and handled with a simple solution. Original theoretical developments are presented. Simulation and experimental results validate the proposed strategy.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteMulti-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of ...
-
Communication avec acteMEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel;
SEMAIL, Eric;
KESTELYN, Xavier;
NGUYEN, Ngac Ky (EPE Conference, 2013)
This paper presents a specific control strategy of double-ended inverter system for wide-speed range of open-winding five phase PM machines. Different virtual winding configurations (star, pentagon, pentacle and bipolar) ... -
Communication avec acteMEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; LU, Li;
SEMAIL, Eric;
KESTELYN, Xavier;
NGUYEN, Ngac Ky (IEEE - Institute of Electrical and Electronics Engineers, 2012)
A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based ... -
Communication avec acteThis paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in series for reducing the number ...
-
Conférence invitéeThis paper analyzes two dual-motor fault-tolerant topologies. The first one supplies independently both machines while the second one connects them in series for reducing the number of transistors. For a given DC-link ...