A Comparative Study of Two Fault-Tolerant Dual-Motor Drive Topologies Under Short-Circuit Inverter Switch Fault
Communication avec acte
Date
2015Résumé
This paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in series for reducing the number of transistors and offering a capability of energy management between the sources. Inverter short-circuit fault is considered. Based on the peak-currents obtained in simulation in degraded mode without reconfiguration and with two different reconfiguration strategies, the two proposed topologies can be compared in economic and technical aspects.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteDOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; SEMAIL, Eric; NGUYEN, Ngac Ky (SGE 2016, 2016)Dans le cadre d’une commande en mode dégradé d’un entrainement comprenant deux machines polyphasées connectées en série et pilotées de façon indépendante, l’article s’intéresse à analyser la performance de l’entrainement ...
-
Communication avec acteThis paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in series for reducing the number ...
-
Conférence invitéeThis paper analyzes two dual-motor fault-tolerant topologies. The first one supplies independently both machines while the second one connects them in series for reducing the number of transistors. For a given DC-link ...
-
Article dans une revue avec comité de lectureDOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; SEMAIL, Eric; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2017)This paper analyzes two fault-tolerant dualmultiphase motor drives, a series connected topology and a standard H-bridge topology. Previous studies have shown that the series connected topology is appropriate to an aerospace ...
-
Communication avec acteDOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; TRABELSI, Mohamed; SEMAIL, Eric; NGUYEN, Ngac Ky (SDEMPED, 2017)This paper deals with the fault effects analysis and diagnosis in 6-Φ PMSM designed for aerospace applications. The addressed work aims to analyze the features offered by the space vector theory applied to these systems ...