Biocompatibility of sol-gel hydroxyapatite-titania composite and bilayer coatings

Article dans une revue avec comité de lecture
Author
SIDANE, Djahida
302269 Université Abderrahmane Mira [Université de Béjaïa] = University of Béjaïa = جامعة بجاية [UB]
RAMMAL, H.
7569 Université de Reims Champagne-Ardenne [URCA]
BELJEBBAR, A.
7569 Université de Reims Champagne-Ardenne [URCA]
GANGLOFF, S.C.
7569 Université de Reims Champagne-Ardenne [URCA]
CHICOT, Didier
1252 Laboratoire de Mécanique de Lille - FRE 3723 [LML]
VELARD, V.
7569 Université de Reims Champagne-Ardenne [URCA]
KHIREDDINE, Hafit
302269 Université Abderrahmane Mira [Université de Béjaïa] = University of Béjaïa = جامعة بجاية [UB]
KERDJOUDJ, H.
7569 Université de Reims Champagne-Ardenne [URCA]
ccMONTAGNE, Alex
211915 Mechanics surfaces and materials processing [MSMP]

URI
http://hdl.handle.net/10985/11964
DOI
10.1016/j.msec.2016.11.129
Date
2017
Journal
Materials Science and Engineering: C

Abstract

Titania-Hydroxyapatite (TiO2/HAP) reinforced coatings are proposed to enhance the bioactivity and corrosion resistance of 316L stainless steel (316L SS). Herein, spin- and dip-coating sol-gel processes were investigated to construct two kinds of coatings: TiO2/HAP composite and TiO2/HAP bilayer. Physicochemical characterization highlighted the bioactivity response of the TiO2/HAP composite once incubated in physiological conditions for 7 days whereas the TiO2/HAP bilayer showed instability and dissolution. Biological analysis revealed a failure in human stem cells adhesion on TiO2/HAP bilayer whereas on TiO2/HAP composite the presence of polygonal shaped cells, possessing good behaviour attested a good biocompatibility of the composite coating. Finally, TiO2/HAP composite with hardness up to 0.6 GPa and elastic modulus up to 18 GPa, showed an increased corrosion resistance of 316L SS. In conclusion, the user-friendly sol-gel processes led to bioactive TiO2/HAP composite buildup suitable for biomedical applications.

Files in this item

Name:
MSMP_MSEC_2017_MONTAGNE.pdf
Size:
1.783Mb
Format:
PDF
View/Open

Collections

  • Laboratoire Mechanics, Surfaces and Materials Processing (MSMP)

Related items

Showing items related by title, author, creator and subject.

  • Multiscale and multicycle instrumented indentation to determine mechanical properties: Application to the BK7 crown borosilicate 
    Article dans une revue avec comité de lecture
    BENTOUMI, Mohamed; BOUZID, Djamel; BENZAAMA, H; MEJIAS, Alberto; KOSSMAN, Stephania; IOST, Alain; CHICOT, Didier; ccMONTAGNE, Alex (Cambridge University Press (CUP), 2017)
    In this work, nano, micro, and macro-indentation tests under standard or multicycle loading conditions were performed for studying the mechanical behavior of a crown borosilicate glass sample with the objective to study ...
  • Hydroxyapatite-TiO2-SiO2-Coated 316L Stainless Steel for Biomedical Application 
    Article dans une revue avec comité de lecture
    SIDANE, Djahida; KHIREDDINE, Hafit; BIR, Fatima; YALA, Sabeha; CHICOT, Didier; ccMONTAGNE, Alex (Springer Verlag/ASM International, 2017)
    This study investigated the effectiveness of titania (TiO2) as a reinforcing phase in the hydroxyapatite (HAP) coating and silica (SiO2) single-layer as a bond coat between the TiO2-reinforced hydroxyapatite (TiO2/HAP) ...
  • Multi-scale approach of the instrumented indentation technique on the fracture toughness estimation 
    Communication sans acte
    MEJIAS, A; CHICOT, Didier; DECOOPMAN, Xavier; ROUDET, Francine; IOST, Alain; ccMONTAGNE, Alex (SF2M, 2015)
    Instrumented Indentation Technique (IIT) is widely used to determine the mechanical properties of materials. The elastic modulus is usually determined by applying the methodology proposed by ...
  • Application de l’indentation a l’etude de la tenacite apparente d’interface dans un beton arme 
    Communication sans acte
    GRAIRIA, Said; CHRAIT, Yacine; IOST, Alain; CHICOT, Didier; ccMONTAGNE, Alex (2016)
    La détermination de l’adhérence d’un béton sur une armature en acier fait très souvent appel à des techniques difficiles à mettre en œuvre et nécessite la plupart du temps une préparation longue et complexe de l’échantillon. ...
  • A new approach of the Oliver and Pharr model to fit the unloading curve from instrumented indentation testing 
    Article dans une revue avec comité de lecture
    KOSSMAN, Stephania; IOST, Alain; CHICOT, Didier; ccCOOREVITS, Thierry (Cambridge University Press (CUP), 2017)
    The unloading part of a load–displacement curve from instrumented indentation tests is usually approximated by a power law (Oliver and Pharr model), where the load is the dependent variable. This approach generally fits ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales