Inverter Open Circuit Faults Diagnosis in Series-Connected Six-Phases Permanent Magnet Drive
Communication avec acte
Date
2017Abstract
This paper deals with the fault effects analysis and diagnosis in 6-Φ PMSM designed for aerospace applications. The addressed work aims to analyze the features offered by the space vector theory applied to these systems for fault detection and identification purposes. The paper starts with a presentation of the overall electric drive system structure and its control. Then, fault effects analysis under faulty operation mode of the 6-leg voltage source inverter is presented considering the space vector theory. Based on such analysis, an accurate FDI process is designed for these applications. All results are verified analytically and through simulation software using Matlab/Simulink.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Communication avec acteDOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; SEMAIL, Eric; NGUYEN, Ngac Ky (SGE 2016, 2016)Dans le cadre d’une commande en mode dégradé d’un entrainement comprenant deux machines polyphasées connectées en série et pilotées de façon indépendante, l’article s’intéresse à analyser la performance de l’entrainement ...
-
Article dans une revue avec comité de lectureDOS SANTOS MORAES, Tiago José; SEMAIL, Eric; MEINGUET, Fabien; GUERIN, Mael; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2018)This paper presents an extension of previous methods in order to find electrical series-connections between multiphase machines allowing the independent control of each one of them. These new electrical series-connections ...
-
Article dans une revue avec comité de lectureDOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; SEMAIL, Eric; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2017)This paper analyzes two fault-tolerant dualmultiphase motor drives, a series connected topology and a standard H-bridge topology. Previous studies have shown that the series connected topology is appropriate to an aerospace ...
-
Article dans une revue avec comité de lectureJOSE DOS SANTOS MORAES, Tiago; TRABELSI, Mohamed; NGUYEN, Ngac Ky; SEMAIL, Eric; MEINGUET, Fabien (Institution of Engineering and Technology, 2020)This paper investigates a real-time fault diagnostic of a transportation system which needs two drives with fault-tolerance capabilities. Because of constraints on the mass of the system and on the cost of the Voltage ...
-
Communication avec acteThis paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in series for reducing the number ...