Canal lock variable speed hydropower turbine design and control

Article dans une revue avec comité de lecture
Author
ZHANGH, Jian
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
LEONTIDIS, Vlasios
531216 Laboratoire de Mécanique des Fluides de Lille – Kampé de Fériet - UMR 9014 [LMFL]
DAZIN, Antoine
531216 Laboratoire de Mécanique des Fluides de Lille – Kampé de Fériet - UMR 9014 [LMFL]
TOUNZI, Abdelmounaim
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
DELARUE, Phillipe
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
CAIGNAERT, Guy
531216 Laboratoire de Mécanique des Fluides de Lille – Kampé de Fériet - UMR 9014 [LMFL]
PIRIOU, Francis
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
LIBAUX, Antoine
302313 EDF [EDF]

URI
http://hdl.handle.net/10985/15020
DOI
10.1049/iet-rpg.2018.5312
Date
2018
Journal
IET Renewable Power Generation

Abstract

The design of a novel submerged hydraulic turbine for producing electricity by converting the available hydropower on canal locks during raising and lowering ships, but with the minimum overall impact on the facility, is being considered. The hydraulic head in such applications is low (few meters) and varies over time (from its maximum value down to zero) resulting in a low potential conversion of hydraulic head in electrical energy. The study involves the modification of the hydraulic transient system, the design and performance estimation of a hydraulic turbine. Based on the performance curves, a permanent magnet Vernier generator is designed. The models of hydraulic turbine and generator are added to the system model and simulations results of the whole system are presented.

Files in this item

Name:
LMFL_IETRPG_2018_DAZIN.pdf
Size:
2.089Mb
Format:
PDF
View/Open

Collections

  • Laboratoire de Mécanique des Fluides de Lille (LMFL)

Related items

Showing items related by title, author, creator and subject.

  • Quantitative Design of a High Performance Permanent Magnet Vernier Generator 
    Article dans une revue avec comité de lecture
    ZHANG, Jian; TOUNZI, Abdelmounaim; DELARUE, Phillipe; PIRIOU, Francis; LEONTIDIS, Vlasios; DAZIN, Antoine; CAIGNAERT, Guy; LIBAUX, Antoine (Institute of Electrical and Electronics Engineers, 2017)
    Permanent-magnet vernier machines are becoming more and more attractive due to their high torque density and low-speed operating capabilities. This paper investigates the effects of the magnet thickness, magnet pole arc ...
  • Experimental validation of an ultrasonic flowmeter for unsteady flows 
    Article dans une revue avec comité de lecture
    LEONTIDIS, Vlasios; CUVIER, Christophe; CAIGNAERT, Guy; DUPONT, Patrick; ROUSSETTE, Olivier; FAMMERY, Simon; NIVET, P.; DAZIN, Antoine (IOP Publishing, 2018)
    An ultrasonic flowmeter was developed for further applications in cryogenic conditions and for measuring flow rate fluctuations in the range of 0 to 70 Hz. The prototype was installed in a flow test rig, and was validated ...
  • Transient behavior of a radial vaneless diffuser 
    Communication avec acte
    DAZIN, Antoine; DUPONT, Patrick; CAIGNAERT, Guy; BOIS, Gérard (ASME, 2011)
    The paper refers to the behavior of a radial flow pump vaneless diffuser during a starting period. Results obtained with a 1D numerical model are compared with some new experimental data which have been obtained using 2D/3C ...
  • Analysis of Cavitation Instabilities in a Four-Blade Inducer 
    Article dans une revue avec comité de lecture
    COUTIER-DELGOSHA, Olivier; DAZIN, Antoine; CAIGNAERT, Guy; BOIS, Gérard (HPC - Hindawi Publishing Corporation, 2012)
    The cavitating behavior of a four-blade inducer tested in the LML laboratory large test facility is considered in the present paper. Experimental investigations based on unsteady pressure measurements and records from a ...
  • Modeling of Hydro-Pneumatic Energy Storage Using Pump Turbines 
    Communication avec acte
    ORTEGO, Egoï; DAZIN, Antoine; CAIGNAERT, Guy; COLAS, Frédéric; COUTIER-DELGOSHA, Olivier (SHF - Société Hydrotechnique de France, 2011)
    Modelling of a hydro-pneumatic energy storage system is presented in this paper. Hydro pneumatic storage aims to combine the good efficiency of hydraulic energy conversion and the space flexibility of pneumatic storage. ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales