• français
    • English
    français
  • Login
Help
View Item 
  •   Home
  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille
  • View Item
  • Home
  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Control Strategies for Non-sinusoidal Multiphase PMSM Drives in Faulty Modes under Constraints on Copper Losses and Peak Phase Voltage

Article dans une revue avec comité de lecture
Author
VU, Duc Tan
DOS SANTOS MORAES, Tiago Jose
ccSEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
NGUYEN, Ngac Ky

URI
http://hdl.handle.net/10985/15157
Date
2019
Journal
IET Electric Power Applications

Abstract

In the context of future Permanent Magnet Synchronous Machines (PMSMs) with a high number of phases (>7) in integrated drives, this paper proposes several control strategies when multiphase PMSMs with non-sinusoidal back electromotive forces (back-EMFs) operate in healthy and open-circuit faults. In all operation modes, the considered constraint on current is related to the maximum root mean square (RMS) current allowable in one phase of the machine. The constraint on voltage limits the maximum peak value of the phase voltage determined by the DC-bus voltage of the converter. When one or two phases are open-circuited, to maximize torque and respect the constraints, new current references obtained by several proposed methods in rotating and natural frames are imposed to the machine. Due to the non-sinusoidal waveform of back-EMFs and the considered constraints, numerical computations based on analytical formulations are required to obtain maximal torque-speed characteristics, including the flux-weakening operation. The usefulness of the proposed strategies is verified by numerical and experimental results.

Files in this item

Name:
L2EP_IET_2019_VU_SAM.pdf
Size:
5.883Mb
Format:
PDF
View/Open

Collections

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Related items

Showing items related by title, author, creator and subject.

  • Torque optimization of seven phase BLDC machines in normal and degraded modes with constraints on current and voltage 
    Conférence invitée
    VU, Duc Tan; DOS SANTOS MORAES, Tiago José; ccSEMAIL, Eric; NGUYEN, Ngac Ky (2018)
    This paper proposes several easy-to-implement control strategies when seven-phase axial flux brushless DC machines with trapezoidal back electromotive forces operate in normal and faulty modes by taking into account ...
  • Torque Optimization of a Seven-Phase Bi-harmonic PMSM in Healthy and Degraded Mode 
    Conférence invitée
    ZHANG, Hao; ZHAO, Benteng; GONG, Jinlin; XU, Yanliang; VU, Duc Tan; ccSEMAIL, Eric; DOS SANTOS MORAES, Tiago José; NGUYEN, Ngac Ky (IEEE, 2019)
    Compared to sinusoidal machines, a bi-harmonic machine (with only two harmonics of similar value in the electromotive force spectrum) can develop torque of comparable values under three kinds of supply: with only first or ...
  • Optimal torque/speed characteristics of a Five-Phase Synchronous Machine under Peak or RMS current control strategies 
    Communication avec acte
    DOS SANTOS MORAES, Tiago Jose; WU, Hailong; ccSEMAIL, Eric; VU, Duc Tan; NGUYEN, Ngac Ky (IEEE, 2020)
    Torque density is usually improved by injecting the third current harmonic for five-phase permanent magnet synchronous machine (PMSM). It increases the degrees of freedom of a multiphase drive. However, it also separates ...
  • Fault-tolerant Control for 7-phase Non-sinusoidal Permanent Magnet Machines with One Opened Phase 
    Communication avec acte
    YANAGIHARA, Keitaro; VU, Duc Tan; GONG, Jinlin; ccSEMAIL, Eric; DOS SANTOS MORAES, Tiago José; NGUYEN, Ngac Ky (IEEE, 2019)
    This paper presents new fault-tolerant control strategies for field-oriented control of 7-phase non-sinusoidal permanent magnet (PM) machines supplied by voltage source inverters (VSI). Single phase open-circuit fault is ...
  • Commande en Mode Dégradé d’un Drive avec Deux Machines 6 phases en Série 
    Communication avec acte
    DOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; ccSEMAIL, Eric; NGUYEN, Ngac Ky (SGE 2016, 2016)
    Dans le cadre d’une commande en mode dégradé d’un entrainement comprenant deux machines polyphasées connectées en série et pilotées de façon indépendante, l’article s’intéresse à analyser la performance de l’entrainement ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales