JavaScript is disabled for your browser. Some features of this site may not work without it.

Multilayer CdHgTe-based infrared detector: 2D/3D microtomography, synchrotron emission and finite element modelling with stress distribution at room temperature and 100 K

Article dans une revue avec comité de lecture
Author
LEBAUDY, Anne-Laure
178323 Laboratoire d'Etude des Microstructures et de Mécanique des Matériaux [LEM3]
PESCI, Raphaël
178323 Laboratoire d'Etude des Microstructures et de Mécanique des Matériaux [LEM3]
PIOTROWSKI, Boris
178323 Laboratoire d'Etude des Microstructures et de Mécanique des Matériaux [LEM3]

URI
http://hdl.handle.net/10985/18176
DOI
10.1016/j.mtla.2019.100511
Date
2020
Journal
Materialia

Abstract

The mechanical behaviour of a CdHgTe-based infrared detector was evaluated after processing at several temperatures to determine the impact of thermomechanical loading on residual stress and reliability. The architecture of the detector was first entirely characterized, relying on SEM, X-ray microtomography and diffraction analysis, in order to get the nature, the morphology and the crystallographic orientation of all the constitutive layers, and in particular the indium solder bumps. The results notably showed the unexpected single crystal aspect of the indium bumps with a repeatable truncated cone geometry. To obtain the thermomechanical response of the structure after processing and in the range of operating temperatures (from 430 K to 100 K), a 3D Finite Element model was then developed. As expected, the numerical results showed a stress gradient evolution in the structure from high to low temperatures, with high loca njvvl stress around 30 MPa in the CdHgTe at 100 K, mainly due to the thermal expansion coefficient mismatch between the different layers. They highlighted the significant influence of the geometry and the single crystal nature of the bumps as well as the behaviour law of the different materials.

Files in this item

Name:
LEM3_MATER_2020_PESCI.pdf
Size:
4.721Mb
Format:
PDF
Embargoed until:
2020-10-01
View/Open

Collections

  • Laboratoire d'Etude des Microstructures et de Mécanique des Matériaux (LEM3)

Related items

Showing items related by title, author, creator and subject.

  • Mechanical properties of a nanoporous membrane used in implantable medical devices. Correlation between experimental characterization and 2D numerical simulation 
    Article dans une revue avec comité de lecture
    CRISTOFARI, François; PIOTROWSKI, Boris; PESCI, Raphaël (Elsevier, 2017)
    Nanoporous membranes are used for the elaboration of implantable medical devices. In order to guaranty their integrity after implantation in a patient body, it is necessary to characterize the microstructure and the ...
  • X-ray Diffraction Residual Stress Measurement at Room Temperature and 77 K in a Microelectronic Multi-layered Single-Crystal Structure Used for Infrared Detection 
    Article dans une revue avec comité de lecture
    LEBAUDY, Anne-Laure; PESCI, Raphaël; FENDLER, M. (Institute of Electrical and Electronics Engineers, 2018)
    The electronic assembly considered in this study is an infrared (IR) detector consisting of different layers, including (111) CdHgTe and (100) silicon single crystals. The processing steps and the low working temperature ...
  • Comparison of residual stresses on long rolled profiles measured by X-ray diffraction,ring core and the sectioning methods and simulated by FE method 
    Article dans une revue avec comité de lecture
    BOUFFIOUX, Chantal; PESCI, Raphaël; BOMAN, Romain; CAILLET, Nicolas; PONTHOT, Jean-Philippe; HABRAKEN, Anne-Marie (Elsevier, 2016)
    Sheet piles are produced by hot rolling, a cooling step and, if required, by a straightening operation. Numerical simulations indicate that the stress field is almost homogeneous through the thickness, justifying the ...
  • Development and mechanical characterization of porous titanium bone substitutes 
    Article dans une revue avec comité de lecture
    BARBAS, Alexandre; BONNET, Anne-Sophie; LIPINSKI, Paul; PESCI, Raphaël; DUBOIS, Guillaume (Elsevier, 2012)
    Commercially Pure Porous Titanium (CPPTi) can be used for surgical implants to avoid the stress shielding effect due to the mismatch between the mechanical properties of titanium and bone. Most researchers in this area ...
  • Interaction of bone-dental implant with new ultra low modulus alloy using a numerical approach 
    Article dans une revue avec comité de lecture
    PIOTROWSKI, Boris; BAPTISTA, André; PATOOR, Etienne; BRAVETTI, Pierre; EBERHARDT, André; LAHEURTE, Pascal (Elsevier, 2014)
    Although mechanical stress is known as being a significant factor in bone remodeling, most implants are still made using materials that have a higher elastic stiffness than that of bones. Load transfer between the implant ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales