Impact of Grid-forming Converter on Electromechanical Oscillations

Communication avec acte
Author
ccBOUKHENFOUF, Johan
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
GUILLAUD, Xavier
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
120930 Centrale Lille
BRUYERE, Antoine
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
120930 Centrale Lille

URI
http://hdl.handle.net/10985/24241
DOI
10.1109/powertech55446.2023.10202756
Date
2023-06

Abstract

As distributed generation increases, it is essential to study its impact on the grid dynamics. This paper focuses on understanding the influence of the emergent technology of Grid-Forming converters on the electromechanical oscillations of the power system. Interactions among synchronous generators and gridforming converters are analyzed thanks to simplified models. These highlight the similarities of both sources, and thus, explain the participation of the converter in the oscillation. They also revealed the differences that justify the damping effect of Grid-Forming converter. This conclusion, obtained with simplified models, is validated with a small-signal stability analysis of a detailed model in the dq0-frame.

Files in this item

Name:
L2EP_POWERTECH_2023_BOUKHENFOUF
Size:
904.1Kb
Format:
PDF
Description:
L2EP_POWERTECH_2023_BOUKHENFOUF
Embargoed until:
2024-01-01
View/Open

Collections

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Related items

Showing items related by title, author, creator and subject.

  • Reduce Order Modeling of the modular multilevel DC/DC converter (M2DC) for HVDC grid 
    Communication avec acte
    ccSHAFIQUE, Ghazala; ccBOUKHENFOUF, Johan; ccGRUSON, Francois; SAMIMI, Shabab; ccDELARUE, Philippe; ccLE MOIGNE, Philippe; ccCOLAS, Frédéric; MERLIN, Michael; ccGUILLAUD, Xavier (2023-10)
    The Modular Multi-Level DC-DC Converter (M2DC) is an attractive non-isolated DC-DC converter topology for HVDC grid. In order to carry out MTDC grid stability studies, the development of reduce order models of converters ...
  • Modular Multilevel DC Converter : Impact of the Control on the Design and Efficiency 
    Communication avec acte
    BOUKHENFOUF, Johan; VERMEERSCH, Pierre; DELARUE, Philippe; LEMOIGNE, Philippe; COLAS, Frédéric; GUILLAUD, Xavier; ccGRUSON, Francois (IEEE, 2023-09)
    The Modular Multilevel DC Converter is an attractive non-isolated topology to inter- connect High Voltage DC Links. This paper presents the interaction among control, component design and efficiency of this converter. The ...
  • Small signal analysis of DC voltage control based on a virtual resistance of DC/DC converter integrated in a multiterminal DC grid 
    Article dans une revue avec comité de lecture
    ccSHAFIQUE, Ghazala; ccBOUKHENFOUF, Johan; ccGRUSON, Francois; SAMIMI, Shabab; ccCOLAS, Frédéric; ccGUILLAUD, Xavier (Institution of Engineering and Technology (IET), 2024-09)
    AbstractThe future multi‐terminal direct‐current (MTDC) grid will require the interconnection of point‐to‐point high‐voltage (HV) DC links with different specifications such as DC voltage level, system grounding configuration ...
  • Effect of Using PLL-Based Grid-Forming Control on Active Power Dynamics Under Various SCR 
    Communication avec acte
    ROKROK, Ebrahim; QORIA, Taoufik; BRUYERE, Antoine; BRUNO, François; GUILLAUD, X. (2019)
    This paper investigates the effect of using phaselocked loop (PLL) on the performance of a grid-forming controlled converter. Usually, a grid-forming controlled converter operates without dedicated PLL. It is shown that ...
  • Procédé de commande d'un moteur électrique à 3 phases alimentée indépendamment 
    Brevet
    BRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; ccSEMAIL, Eric; ccKESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)
    Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales