Analysis of Unsteadinesses in a Vaned Diffuser of Centrifugal Machinery.
Communication avec acte
Date
2013Résumé
The aim of this article is to present experimental results obtained on a fan composed of a radial impeller matched with a vaned diffuser. There is no volute downstream to the diffuser. Consequently the diffuser outlet is at free air. The particularity of this machinery is that the diffuser design flow rate corresponds to 80% of the impeller one. Investigations have been made for five different flow rates. Global performances of the machine are evaluated thanks to pressure measurements and averaged velocities obtain with a three holes probe, at nine angular positions at diffuser inlet and outlet just as five radial positions in a middle section of a blade-to-blade passage. In order to better characterize separations observed in previous experimental and numerical studies unsteady pressure measurement campaigns have been carried out. The transducers are located at five positions on the pressure face and four positions on the suction face on diffuser vanes in a blade-to-blade plane. For each position, three transducers are located at three different heights, from hub to shroud. Unsteadinesses revealed by these measurements just as theirs effects on the diffuser performance are analysed.
Fichier(s) constituant cette publication
- Nom:
- LML_CFM_2013_CHERDIEU.pdf
- Taille:
- 1.585Mo
- Format:
- Description:
- Document article principal
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureDUPONT, Patrick; CAVAZZINI, Giovanna; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (2013)The paper presents analysis of the performance and the internal flow behaviour in the vaned diffusor of a radial flow pump using PIV (Particle Image Velocimetry) and pressure probe traverses. PIV measurements have already ...
-
Comparaisons between numerical calculations and measurements in the vaned diffusor of SHF impeller Communication avec acteDUPONT, Patrick; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (2012)The paper presents analysis of the performance and the internal flow behaviour in the vaned diffusor of a radial flow pump using PIV technique and pressure probe traverses. PIV measurements have been performed at mid height ...
-
Communication avec acteDUPONT, Patrick; CAVAZZINI, Giovanna; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (2013)The paper presents the numerical and experimental analysis of performance and internal flow behaviour in the vaned diffuser of a radial flow pump (Fig. 1) using PIV technique (Fig. 2), pressure probe traverses and numerical ...
-
NUMERICAL AND EXPERIMENTAL INVESTIGATIONS IN A VANED DIFFUSER OF SHF IMPELLER: FLUID LEAKAGE EFFECT Communication avec acteDUPONT, Patrick; CAVAZZINI, Giovanna; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (2013)The paper presents the analysis of the performance and the internal flow behaviour in the vaned diffuser of a radial flow pump using PIV technique, pressure probe traverses and numerical simulations. PIV measurements have ...
-
Article dans une revue avec comité de lectureDUPONT, Patrick; CAVAZZINI, Giovanna; PAVESI, Giorgio; CHERDIEU, Patrick; BOIS, Gérard; ROUSSETTE, Olivier; DAZIN, Antoine; BAYEUL-LAINÉ, Annie-Claude (EDP Sciences, 2015)The paper presents the analysis of the performance and the internal flow behaviour in the vaned diffuser of a radial flow pump using PIV (particles image velocimetry) technique, pressure probe traverses and numerical ...