Application of a Combined Active Control and Fault Detection Scheme to an Active Composite Flexible Structure.
Article dans une revue avec comité de lecture
Date
2006Journal
MechatronicsAbstract
In this paper, the problem of increasing reliability of active control procedure is considered. Indeed, a design method of rejection perturbation in presence of potentially faults, on a flexible structure with integrated piezo-ceramics, is presented. The piezo-ceramics are used as actuators and sensors. A single unit based solution, which handles both control action and fault diagnosis is proposed. The algorithm uses H∞ optimization techniques. A full order model of the structure is first obtained via both finite-element (FE) approach and identification procedure. This model is then reduced in order to be used in our robust approach. By a suitable choice of weightings functions, the provided method is able to reject disturbance robustly and to estimate occurred faults. The case of sensors and actuators faults is discussed. The choice of weightings for diagnosis and control systems is also tackled. Finally, the effectiveness of this integrated method is confirmed by both simulation and experimental results.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureA new approach for vibration reduction of flexible structures subject to damage is here proposed, based on modal H∞H∞-norm control. Considering that structural damage provokes different effects on each vibration mode, the ...
-
Article dans une revue avec comité de lectureFENDZI, Claude; COFFIGNAL, Gérard; MECHBAL, Nazih; GUSKOV, Mikhail; RÉBILLAT, Marc (SAGE Publications (UK and US), 2016)This paper presents a temperature compensation method for Lamb wave structural health monitoring. The proposed approach considers a representation of the piezo-sensor signal through its Hilbert transform that allows one ...
-
Article dans une revue avec comité de lectureDamage-tolerant active control (DTAC) is a recent research area that encompasses control design methodologies resulting from the application of fault-tolerant control methods to vibration control of structures subject to ...
-
Article dans une revue avec comité de lectureActive vibration control of flexible structures has received considerable attention in the latest decades. However, several related control problems remain open to new investigations such as robust performance, spillover ...
-
Communication avec acteFENDZI, Claude; MOREL, Julien; COFFIGNAL, Gérard; MECHBAL, Nazih; GUSKOV, Mikhail; RÉBILLAT, Marc (2014)This paper examines an important challenge in ultrasonic structural health monitoring (SHM), which is the problem of the optimal placement of sensors in order to accurately detect and localize damages. The goal of this ...