Open Switch Fault Effects Analysis (OSFEA) in Five Phase PMSM Designed for Aerospace Application

Communication avec acte
Author
TRABELSI, Mohamed
ccSEMAIL, Eric
MEINGUET, Fabien
48530 Thales Alenia Space [Toulouse] [TAS]
NGUYEN, Ngac Ky
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]

URI
http://hdl.handle.net/10985/11322
DOI
10.1109/SPEEDAM.2016.7525939
Date
2016

Abstract

This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For these demanding applications, the fault tolerance and the reliability of the PMSM as well as the power converter are of high great importance. The addressed work aims essentially to analyze the dynamic of the measured phase currents in post-fault operation with a real-time fault diagnostic purposes in the VSI. It starts with a presentation of the electric drive system structure and its control used in pre-fault and post-fault operation of the electric drive system. Then, fault mode effects analysis (FMEA) on the system is considered. It is based on the Generalized Vectorial Formalism (GVF) and Space Vector Theory (SVT). All results are verified analytically and through simulation software using Matlab/Simulator®. The theoretical development and the simulation results show that the five phase PMSM under inverter faults presents typical characteristics which can be used as better inputs variable for designing a high performance fault diagnostic and classification process.

Files in this item

Name:
L2EP_OSFEA_SPEEDAM_Semail_2016.pdf
Size:
1.082Mb
Format:
PDF
Description:
article principal
View/Open

Collections

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Related items

Showing items related by title, author, creator and subject.

  • Open Switch Fault Effects Analysis in Five-Phase PMSM Designed for Aerospace Application 
    Communication avec acte
    TRABELSI, Mohamed; ccSEMAIL, Eric; MEINGUET, Fabien; NGUYEN, Ngac Ky (IEEE - Power and Energy Society, 2016)
    This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For such applications, the fault ...
  • Inverter Open Circuit Faults Diagnosis in Series-Connected Six-Phases Permanent Magnet Drive 
    Communication avec acte
    DOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; TRABELSI, Mohamed; ccSEMAIL, Eric; NGUYEN, Ngac Ky (SDEMPED, 2017)
    This paper deals with the fault effects analysis and diagnosis in 6-Φ PMSM designed for aerospace applications. The addressed work aims to analyze the features offered by the space vector theory applied to these systems ...
  • Open-Switch and Open-Phase Real Time FDI Process for Multiphase PM Synchronous Motors 
    Communication avec acte
    TRABELSI, Mohamed; MEINGUET, Fabien; ccSEMAIL, Eric; NGUYEN, Ngac Ky (ISIE Conference, 2016)
    This paper deals with the real time Fault Detection and Identification (FDI) process of inverter Open Switch Fault (OSF) and Open Phase Fault (OPF) in five-phase PMSM designed for aerospace applications in which the electric ...
  • Inverter Fault Diagnosis of an Electrical Series-Connected Two Sinusoidal Six-Phase Permanent Magnet Machines Drive 
    Article dans une revue avec comité de lecture
    JOSE DOS SANTOS MORAES, Tiago; TRABELSI, Mohamed; NGUYEN, Ngac Ky; ccSEMAIL, Eric; MEINGUET, Fabien (Institution of Engineering and Technology, 2020)
    This paper investigates a real-time fault diagnostic of a transportation system which needs two drives with fault-tolerance capabilities. Because of constraints on the mass of the system and on the cost of the Voltage ...
  • Commande en Mode Dégradé d’un Drive avec Deux Machines 6 phases en Série 
    Communication avec acte
    DOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; ccSEMAIL, Eric; NGUYEN, Ngac Ky (SGE 2016, 2016)
    Dans le cadre d’une commande en mode dégradé d’un entrainement comprenant deux machines polyphasées connectées en série et pilotées de façon indépendante, l’article s’intéresse à analyser la performance de l’entrainement ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales