• français
    • English
    English
  • Ouvrir une session
Aide
Voir le document 
  •   Accueil de SAM
  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)
  • Voir le document
  • Accueil de SAM
  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)
  • Voir le document
JavaScript is disabled for your browser. Some features of this site may not work without it.

Lower-limb lengths and angles in children older than six years: Reliability and reference values by EOS® stereoradiography

Article dans une revue avec comité de lecture
Auteur
RAMPAL, Virginie
466360 Institut de Biomecanique Humaine Georges Charpak
ROHAN, Pierre-Yves
466360 Institut de Biomecanique Humaine Georges Charpak
ASSI, Ayman
GHANEM, Ismat
ROSELLO, O.
SIMON, A.-L.
GAUMETOU, E.
MERZOUG, V.
SKALLI, Wafa
466360 Institut de Biomecanique Humaine Georges Charpak
WICART, P.

URI
http://hdl.handle.net/10985/16605
DOI
10.1016/j.otsr.2017.10.007
Date
2018
Journal
Revue de Chirurgie Orthopédique et Traumatologique

Résumé

Lower-limb alignment in children is classically assessed clinically or based on conventional radiography, which is associated with projection bias. Low-dose biplanar radiography was described recently as an alternative to conventional imaging. The primary objective of this study was to assess the reliability of length and angle values inferred from 3D reconstructions in children seen in everyday practice. The secondary objective was to obtain reference values for goniometry parameters in children. The paediatric reliability study was done in 18 volunteers who were divided into three groups based on whether they were typically developing (TD) children, had skeletal development abnormalities, or had cerebral palsy. The reference data were obtained in 129 TD children. Each study participant underwent biplanar radiography with 3D reconstruction performed by experts and radiology technicians. Goniometry parameters were computed automatically. Reproducibility was assessed based on the intra-class coefficient (ICC) and the ISO 5725 standard (standard deviation of reproducibility, SDR). For length parameters, the ICCs ranged from 0.94 to 1.00 and the SDR from 2.1 to 3.5 mm. For angle parameters, the ICC and SDR ranges were 0.60–0.95 and 0.9°–4.6°, respectively. No significant differences were found across experts or radiology technicians. Age-specific reference data are reported. These findings confirm the reliability of low-dose biplanar radiography for assessing lower-limb parameters in children seen in clinical practice. In addition, the study provides reference data for commonly measured parameters.

Fichier(s) constituant cette publication

Nom:
IBHGC-OTSR-Rampal-2018.pdf
Taille:
391.8Ko
Format:
PDF
Voir/Ouvrir

Cette publication figure dans le(s) laboratoire(s) suivant(s)

  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)

Documents liés

Visualiser des documents liés par titre, auteur, créateur et sujet.

  • Combined 3D analysis of lower-limb morphology and function in children with idiopathic equinovarus clubfoot: A preliminary study 
    Article dans une revue avec comité de lecture
    RAMPAL, Virginie; ROHAN, Pierre-Yves; PILLET, Hélène; BONNET-LEBRUN, Aurore; FONESCA, Mickael; DESAILLY, Eric; WICART, Philippe; SKALLI, Wafa (Elsevier Masson, 2020)
    Introduction In children treated for idiopathic equinovarus clubfoot (EVCF), the relation between morphologic defects on clinical examination and standard X-ray on the one hand and functional abnormalities on the other is ...
  • Assessing 3D paediatric foot morphology using low-dose biplanar radiography: Parameter reproducibility and preliminary values 
    Article dans une revue avec comité de lecture
    RAMPAL, Virginie; ROHAN, Pierre-Yves; SAKSIK, Rebekah; WICART, Philippe; SKALLI, Wafa (Elsevier Masson, 2018)
    The physical examination and weight-bearing radiography are the two main available methods for assessing the feet and lower limbs. The anatomy and function of these two structures interact with each other. These two ...
  • Development and evaluation of a new methodology for Soft Tissue Artifact compensation in the lower limb 
    Article dans une revue avec comité de lecture
    LAHKAR, Bhrigu K.; ROHAN, Pierre-Yves; ASSI, Ayman; PILLET, Helene; BONNET, Xavier; THOREUX, Patricia; SKALLI, Wafa (Elsevier BV, 2021)
    Skin Marker (SM) based motion capture is the most widespread technique used for motion analysis. Yet, the accuracy is often hindered by Soft Tissue Artifact (STA). This is a major issue in clinical gait analysis where ...
  • Alteration of the sitting and standing movement in adult spinal deformity 
    Article dans une revue avec comité de lecture
    SAAD, Eddy; SEMAAN, Karl; KAWKABANI, Georges; MASSAAD, Abir; SALIBY, Renée Maria; MEKHAEL, Mario; FAKHOURY, Marc; KARAM, Krystel Abi; JABER, Elena; GHANEM, Ismat; LAFAGE, Virginie; SKALLI, Wafa; RACHKIDI, Rami; ASSI, Ayman (Elsevier BV, 2022)
    Adults with spinal deformity (ASD) are known to have spinal malalignment affecting their quality of life and daily life activities. While walking kinematics were shown to be altered in ASD, other functional activities are ...
  • How the type of sagittal alignment defined by Roussouly determines the gait of asymptomatic adult subject 
    Article dans une revue avec comité de lecture
    ASSI, Ayman; BAKOUNY, Ziad; MASSAAD, Abir; LAFAGE, Virginie; SAGHBINI, Elie; KREICHATI, Gaby; SKALLI, Wafa; GHANEM, Ismat (Elsevier Masson, 2016)
    While curvatures of the sagittal spine are known to greatly differ among asymptomatic adult subjects, there are no studies that determine whether this heterogeneous normality affects gait. This study aimed to elucidate the ...

Parcourir

Tout SAMLaboratoiresAuteursDates de publicationCampus/InstitutsCe LaboratoireAuteursDates de publicationCampus/Instituts

Lettre Diffuser la Science

Dernière lettreVoir plus

Statistiques de consultation

Publications les plus consultéesStatistiques par paysAuteurs les plus consultés

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales