Functional evaluation of anterior cruciate ligagment autografts in pre-clinical animal models

Communication sans acte
Author
ccSKALLI, Wafa
TRNKA, Julien
34256 École nationale vétérinaire d'Alfort [ENVA]
MANASSERO, Mathieu
34256 École nationale vétérinaire d'Alfort [ENVA]
VIATEAU, Véronique
34256 École nationale vétérinaire d'Alfort [ENVA]
CAROUX, Julien
1157 Centre des Matériaux [MAT]
2073 Laboratoire Matière Molle et Chimie [MMC]
CORTÉ, Laurent
1157 Centre des Matériaux [MAT]
2073 Laboratoire Matière Molle et Chimie [MMC]
ccROHAN, Pierre-Yves
466360 Institut de Biomecanique Humaine Georges Charpak
ccPILLET, Helene

URI
http://hdl.handle.net/10985/17060
Date
2017

Abstract

Introduction Rupture of the Anterior Cruciate Ligament (ACL) affects about 1 person over 3000 every year. The current standard care is based on ligament reconstruction by autograft from tendon tissues and is considered as the gold standard. Yet, autograft reconstruction presents serious limitations. Recent developments in artificial ligaments are promising and could potentially address the currently growing demand from surgeons and patients for an off-the-shelf alternate solution. However, before these can be commonly used in clinical routine, their biocompatibility and biomechanical performance for the short and long terms must be studied in pre-clinical animal models. Building upon the work of [1], we propose in this contribution a methodology for assessing the biomechanical performance of artificial ligaments, and to provide reference data (autografts) using an animal model (sheep) at 3 months after implantation. Materials and Methods Surgery and specimen preparation 14 fresh frozen lower limbs were used in this study, seven left (autograft implantation) and seven right (contralateral) knees. These were harvested from seven sheep sacrificed 3 months after implantation. The biomechanical analysis of the knees consisted of four successive in vitro experiments: three kinematics tests (flexion-extension, varus-valgus laxity and anterior drawer tests) and a pull-out destructive test. Kinematics analysis: flexion-extension and laxity tests The kinematic analysis was performed using specific motorized devices adapted from previously described and validated ones [1]. The protocol combined motion analysis of tripods screwed in the bony structures and 3D personalized reconstruction (figure 1) from low-dose X-ray system (EOS, EOS Imaging, Paris, France) [1,2,3,4]. Pull-out destructive tests The pull-out tests were performed using an INSTRON 5566 testing machine (Instron Ltd., Buckingham-shire, England) instrumented with a 5 kN load cell. After conditioning, a tension load was applied to the specimen (5 mm/min) until total failure. Data analysis: mobility assessment and statistical tests The following parameters were extracted to allow the comparison with the literature [1] (i) Internal rotation Ry (°) value for a 40° flexion angle (Ry_40), (ii) Anterior Tibial Translation (mm) for 100 N loading (ATT_100), (iii) Varus Valgus amplitude (°) at 4 Nm loading (VV_4) and (iv) the Failure load (N) (FL). Results and discussion The results shows a good consistency for kinematic parameters of the contralateral knees. The failure load was clearly different due to the interindividual variability. As concerns the autograft, a reduction of internal rotation during the flexion motion and an increase of the laxity in ATT could be observed. The failure load was also decreased for the grafted knee.

Files in this item

Name:
IBHGC_CESB_2017_ROHAN.pdf
Size:
497.8Kb
Format:
PDF
View/Open

Collections

  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)

Related items

Showing items related by title, author, creator and subject.

  • A wear model to predict damage of reconstructed ACL 
    Article dans une revue avec comité de lecture
    MAEZTU REDIN, Deyo; CAROUX, Julien; ccROHAN, Pierre-Yves; ccPILLET, Helene; CERMOLACCE, Alexia; TRNKA, Julien; MANASSERO, Mathieu; VIATEAU, Véronique; CORTÉ, Laurent (Elsevier BV, 2022-09)
    Impingement with surrounding tissues is a major cause of failure of anterior cruciate ligament reconstruction. However, the complexity of the knee kinematics and anatomical variations make it difficult to predict the ...
  • Development and evaluation of a new methodology for Soft Tissue Artifact compensation in the lower limb 
    Article dans une revue avec comité de lecture
    LAHKAR, Bhrigu K.; ccROHAN, Pierre-Yves; ASSI, Ayman; ccPILLET, Helene; BONNET, Xavier; THOREUX, Patricia; ccSKALLI, Wafa (Elsevier BV, 2021)
    Skin Marker (SM) based motion capture is the most widespread technique used for motion analysis. Yet, the accuracy is often hindered by Soft Tissue Artifact (STA). This is a major issue in clinical gait analysis where ...
  • Subject specific hexahedral Finite Element mesh generation of the pelvis from bi-Planar X-ray images 
    Communication avec acte
    FOUGERON, Nolwenn; ccSKALLI, Wafa; ccROHAN, Pierre-Yves; ccPILLET, Helene (Informa UK Limited, 2017)
    Several Finite Element (FE) models of the pelvis have been developed to comprehensively assess the onset of pathologies and for clinical and industrial applications. However, because of the difficulties associated with the ...
  • Development and evaluation of a new procedure for subject-specific tensioning of finite element knee ligaments 
    Article dans une revue avec comité de lecture
    LAHKAR, Bhrigu K.; ccROHAN, Pierre-Yves; ccPILLET, Helene; THOREUX, Patricia; ccSKALLI, Wafa (Taylor and Francis, 2021)
    Subject-specific tensioning of ligaments is essential for the stability of the knee joint and represents a challenging aspect in the development of finite element models. We aimed to introduce and evaluate a new procedure ...
  • Reliability of B-mode ultrasound and shear wave elastography in evaluating sacral bone and soft tissue characteristics in young adults with clinical feasibility in elderly 
    Article dans une revue avec comité de lecture
    ABOU KARAM, Maher; MUKHINA, Ekaterina; DARAS, Nils; RIVALS, ISabelle; ccPILLET, Helene; ccSKALLI, Wafa; CONNESSON, Nathanael; PAYAN, Yohan; ccROHAN, Pierre-Yves (2022)
    Background: Physiologic aging is associated with loss of mobility, sarcopenia, skin atrophy and loss of elasticity. These factors contribute, in the elderly, to the occurrence of a pressure ulcer (PU). Brightness mode ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales