Coupling Influence on the dq Impedance Stability Analysis for the Three-Phase Grid-Connected Inverter

Article dans une revue avec comité de lecture
Auteur
LI, Chuanyue
QORIA, Taoufik
COLAS, Frédéric
JUN, Liang
22500 Cardiff School of Engineering
WENLONG, Ming
22500 Cardiff School of Engineering
GUILLAUD, X.
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
ccGRUSON, Francois
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]

URI
http://hdl.handle.net/10985/17101
DOI
10.3390/en12193676
Date
2019
Journal
Energies

Résumé

The dq impedance stability analysis for a grid-connected current-control inverter is based on the impedance ratio matrix. However, the coupled matrix brings difficulties in deriving its eigenvalues for the analysis based on the general Nyquist criterion. If the couplings are ignored for simplification, unacceptable errors will be present in the analysis. In this paper, the influence of the couplings on the dq impedance stability analysis is studied. To take the couplings into account simply, the determinant-based impedance stability analysis is used. The mechanism between the determinant of the impedance-ratio matrix and the inverter stability is unveiled. Compared to the eigenvalues-based analysis, only one determinant rather than two eigenvalue s-function is required for the stability analysis. One Nyquist plot or pole map can be applied to the determinant to check the right-half-plane poles. The accuracy of the determinant-based stability analysis is also checked by comparing with the state-space stability analysis method. For the stability analysis, the coupling influence on the current control, the phase-locked loop, and the grid impedance are studied. The errors can be 10% in the stability analysis if the couplings are ignored.

Fichier(s) constituant cette publication

Nom:
L2EP-Energies-Chuanyue-2019.pdf
Taille:
1.207Mo
Format:
PDF
Voir/Ouvrir

Cette publication figure dans le(s) laboratoire(s) suivant(s)

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Documents liés

Visualiser des documents liés par titre, auteur, créateur et sujet.

  • Tuning of Cascaded Controllers for Robust Grid-Forming Voltage Source Converter 
    Communication avec acte
    QORIA, Taoufik; COLAS, Frédéric; GUILLAUD, Xavier; DEBRY, Marie-Sophie; PREVOST, Thierry; ccGRUSON, Francois (IEEE, 2018)
    From the origin of the grid, energy has been delivered to electrical loads mainly by synchronous machines. All the main rules to manage the grid have been based on the electromechanical behavior of these machines which ...
  • Critical clearing time determination and enhancement of grid-forming converters embedding virtual impedance as current limitation algorithm 
    Article dans une revue avec comité de lecture
    QORIA, Taoufik; COLAS, Frédéric; DENIS, Guillaume; PREVOST, Thibault; GUILLAUD, Xavier; ccGRUSON, Francois (Institute of Electrical and Electronics Engineers, 2019)
    The present paper deals with the post-fault synchronization of a voltage source converter based on the droop control. In case of large disturbances on the grid, the current is limited via current limitation algorithms such ...
  • Direct AC Voltage Control for Grid-Forming Inverters 
    Article dans une revue avec comité de lecture
    QORAI, Taoufik; LI, Chuanyue; OUE, Ko; COLAS, Frédéric; GUILLAUD, Xavier; ccGRUSON, Francois (2019)
    Grid-forming inverters usually use inner cascaded controllers to regulate output AC voltage and converter output current. However, at the power transmission system level where the power inverter bandwidth is limited, i.e., ...
  • Tuning of AC voltage-controlled VSC based Linear Quadratic Regulation 
    Communication avec acte
    QORIA, Taoufik; LI, Chuanyue; OUE, Ko; COLAS, Frédéric; GUILLAUD, Xavier; PREVOST, Thibault (IEEE PES PowerTech 2019, 2019)
    In the near future, power converters will be massively introduced in transmission grids due to renewable energy sources and high voltage direct current (HVDC) increase. Voltage Source Converter (VSC) control laws assume ...
  • Tuning of Cascaded Controllers for Robust Grid-Forming Voltage Source Converter 
    Communication avec acte
    QORAI, Taoufik; GRUSON, François; COLAS, Frédéric; GUILLAUD, Xavier; DEBRY, M.-S.; PREVOST, T. (IEEE, 2018-06)
    From the origin of the grid, energy has been delivered to electrical loads mainly by synchronous machines. All the main rules to manage the grid have been based on the electromechanical behavior of these machines which ...

Parcourir

Tout SAMLaboratoiresAuteursDates de publicationCampus/InstitutsCe LaboratoireAuteursDates de publicationCampus/Instituts

Lettre Diffuser la Science

Dernière lettreVoir plus

Statistiques de consultation

Publications les plus consultéesStatistiques par paysAuteurs les plus consultés

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales