Characterization of mouthguards: Impact performance

Article dans une revue avec comité de lecture
Author
ccGUÉRARD, Sandra
BAROU, Jean-Luc
PETIT, Julien
136813 Laboratoire Ondes et Matière d'Aquitaine [LOMA]
POISSON, Philippe
168944 Handicap et système nerveux :Action, communication, interaction: rétablissement de la fonction et de la participation [Bordeaux] [EA4136]

URI
http://hdl.handle.net/10985/17117
DOI
10.1111/edt.12329
Date
2017
Journal
Dental Traumatology

Abstract

Background/Aim: It is difficult to characterize the impact behavior of mouthguards on the basis of their components. Impact behavior tests should be performed on mouthguard formed to simulate their intra-oral performance. The aim of this study was to compare the impact behavior of six models of mouthguards using a standardized experimental protocol. Material and methods: Four commercially available mouth-formed mouthguards (SDI™, Gel Nano™, Opro Shield Gold™ and Kipsta R300™), one mouth-formed mouthguard prototype and one custom-made mouthguard were tested. The procedures recommended by the manufacturers (injecting procedure for custom-made mouthguard and “boil-and- bite” procedures for mouth-formed mouthguards) were used to adapt five samples per model on steel jaws. Impact performances were assessed according to labial aspect thickness and maximum contact load (FMax) during impact using a drop tower. Results: SDI™ and Opro Shield Gold™ had the thinnest labial aspect thickness (P<.01), followed by the Gel Nano™ and the Kipsta R300™ (P<.01) with a thickness of about 3 mm. The prototype and custom-made mouthguard were thicker (almost 4 mm). The custom-made mouthguard, the Kipsta R300™ and the prototype had the best impact performances, but the labial aspect thickness of the Kipsta R300™ was significantly lower than that of the custom-made mouthguard and the prototype. Analysis of force curves and position of the mouthguard on the impacted zone showed that the Kipsta R300™ was less well adapted. Conclusion: Thickness and impact performance are not sufficient criteria to characterize performance of mouthguards.

Files in this item

Name:
I2M_IPDT_2017_GUERARD
Size:
1.032Mb
Format:
PDF
View/Open

Collections

  • Institut de Mécanique et d’Ingénierie de Bordeaux (I2M)

Related items

Showing items related by title, author, creator and subject.

  • Characterization of mouth-formed mouthguards: Thermal performance 
    Article dans une revue avec comité de lecture
    ccGUÉRARD, Sandra; BAROU, Jean-Luc; PETIT, Julien; POISSON, Philippe (Japanese Society for Dental Materials and Devices, 2014)
    This study examined whether the thermo-modeling process suits the thermal properties of the material constituting mouthformed mouthguards (MGs). Five mouth-formed MGs were compared: four commercially available MGs (SDITM, ...
  • Perforation of aluminium alloy thin plates 
    Article dans une revue avec comité de lecture
    ANTOINAT, Léonard; ccKUBLER, Regis; BAROU, Jean-Luc; ccVIOT, Philippe; BARRALLIER, Laurent (Elsevier, 2015)
    Low velocity perforation of aeronautical aluminium alloy sheets 2024 T3 is studied in this paper. After a literature review on recent experiments and models of plate’s perforation, experimental results for 2 thicknesses ...
  • Perforation of aluminium alloy thin plates 
    Article dans une revue avec comité de lecture
    ANTOINAT, Léonard; ccKUBLER, Regis; BAROU, Jean-Luc; ccVIOT, Philippe; BARRALLIER, Laurent (Elsevier, 2015)
    Low velocity perforation of aeronautical aluminium alloy sheets 2024 T3 is studied in this paper. After a literature review on recent experiments and models of plate's perforation, experimental results for 2 thicknesses ...
  • Non-invasive biomechanical characterization of intervertebral discs by shear wave ultrasound elastography: a feasibility study 
    Article dans une revue avec comité de lecture
    DUBOIS, Guillaume; BONNEAU, Dominique; DUBOUSSET, Jean; TANTER, Mickael; GENNISSON, Jean-Luc; ccROUCH, Philippe; ccVERGARI, Claudio (Elsevier, 2014)
    Objectives Although magnetic resonance is widely spread to assess qualitatively disc morphology, a simple method to determine reliably intervertebral disc status is still lacking. Shear wave elastography is a novel technique ...
  • Intervertebral disc characterization by shear wave elastography: an in-vitro preliminary study 
    Article dans une revue avec comité de lecture
    ccVERGARI, Claudio; ccROUCH, Philippe; DUBOIS, Guillaume; BONNEAU, Dominique; DUBOUSSET, Jean; TANTER, Mickael; GENNISSON, Jean-Luc; ccSKALLI, Wafa (2014)
    Patient-specific numerical simulation of the spine is a useful tool both in clinic and research. While geometrical personalization of the spine is no more an issue, thanks to recent technological advances, non-invasive ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales