Prediction of Hip Failure Load: In Vitro Study of 80 Femurs Using Three Imaging Methods and Finite Element Models-The European Fracture Study (EFFECT).
Article dans une revue avec comité de lecture
Auteur
Résumé
Purpose To evaluate the performance of three imaging methods (radiography, dual-energy x-ray absorptiometry DXA, and quantitative computed tomography CT) and that of a numerical analysis with finite element modeling (FEM) in the prediction of failure load of the proximal femur and to identify the best densitometric or geometric predictors of hip failure load.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureCOURVOISIER, Aurélien; BARBOUR, Valéry; SKALLI, Wafa; MITTON, David (Springer Verlag, 2016)PURPOSE: Implants endurance as well as a good clinical tolerance depends on the recovery of a physiological stress distribution within bone after implantation. The purpose of the present work was to develop an alternative ...
-
Article dans une revue avec comité de lectureLANGLAIS, Tristan; DESPRAIRIES, Pierre; PIETTON, Raphaël; DUBOUSSET, Jean; MEAKIN, Judith R.; WINLOVE, Peter C.; VIALLE, Raphaël; SKALLI, Wafa; ROHAN, Pierre-Yves; VERGARI, Claudio (Springer Verlag, 2019)The main function of the intervertebral disc is biomechanical function, since it must resist repetitive high loadings, while giving the spine its flexibility and protecting the spinal cord from over-straining. It partially ...
-
Article dans une revue avec comité de lectureVARDAKASTANI, Vasiliki; SALETTI, Dominique; SKALLI, Wafa; MARY, Pierre; ALLAIN, Jean-Marc; ADAM, Clayton (Elsevier, 2014)Osteogenesis imperfecta (OI) is a heritable disease occurring in one out of every 20,000 births. Although it is known that Type I collagen mutation in OI leads to increased bone fragility, the mechanism of this increased ...
-
Article dans une revue avec comité de lectureGUÉRARD, Sandra; MANASSERO, Mathieu; VIATEAU, Véronique; MIGONNEY, Véronique; SKALLI, Wafa; MITTON, David (techno-press, 2014)This study aimed to assess the biomechanical performance of a new generation of artificial ligament, which can be considered “bioactive” and “biointegrated,” implanted in sheep. Thirty sheep were implanted: 15 sheep received ...
-
In Vivo Assessment of Elasticity of Child Rib Cortical Bone Using Quantitative Computed Tomography Article dans une revue avec comité de lectureZHU, Y.; BERMOND, François; PAYEN DE LA GARANDERIE, J.; PIALAT, J.-B.; SANDOZ, Baptiste; BRIZARD, D.; PRACROS, J.-P.; RONGIERAS, F.; SKALLI, Wafa; MITTON, David (Hindawi, 2017)Elasticity of the child rib cortical bone is poorly known due to the difficulties in obtaining specimens to perform conventional tests. It was shown on the femoral cortical bone that elasticity is strongly correlated with ...