A principal component analysis of the relationship between the external body shape and internal skeleton for the upper body
Article dans une revue avec comité de lecture
Date
2016Journal
Journal of BiomechanicsAbstract
Recent progress in 3D scanning technologies allows easy access to 3D human body envelope. To create personalized human models with an articulated linkage for realistic re-posturing and motion analyses, an accurate estimation of internal skeleton points, including joint centers, from the external envelope is required. For this research project, 3D reconstructions of both internal skeleton and external envelope from low dose biplanar X-rays of 40 male adults were obtained. Using principal component analysis technique (PCA), a low-dimensional dataset was used to predict internal points of the upper body from the trunk envelope. A least squares method was used to find PC scores that fit the PCA-based model to the envelope of a new subject. To validate the proposed approach, estimated internal points were evaluated using a leave-one-out (LOO) procedure, i.e. successively considering each individual from our dataset as an extra-subject. In addition, different methods were proposed to reduce the variability in data and improve the performance of the PCA-based prediction. The best method was considered as the one providing the smallest errors between estimated and reference internal points with an average error of 8.3 mm anterior?posteriorly, 6.7 mm laterally and 6.5 mm vertically. As the proposed approach relies on few or no bony landmarks, it could be easily applicable and generalizable to surface scans from any devices. Combined with automatic body scanning techniques, this study could potentially constitute a new step towards automatic generation of external/internal subject-specific manikins.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureNÉROT, Agathe; SKALLI, Wafa; WANG, Xuguang (Taylor & Francis, 2015)In this study, the accuracy of the joint centres of the manikins generated by RAMSIS and Human Builder (HB), two digital human modelling (DHM) systems widely used in industry for virtual ergonomics simulation, was investigated. ...
-
Article dans une revue avec comité de lectureNÉROT, Agathe; SKALLI, Wafa; WANG, Xuguang (Elsevier, 2018)Defining a subject-specific model of the human body is required for motion analysis in many fields, such as in ergonomics and clinical applications. However, locating internal joint centers from external characteristics ...
-
Article dans une revue avec comité de lectureHuman external shape model is becoming easily available using scanning technology, stereophotogram- metry, or Microsoft Kinect systems. However locating the internal skeleton from the external shape remains a challenging ...
-
Article dans une revue avec comité de lectureNÉROT, Agathe; CHOISNE, Julie; AMABILE, Célia; TRAVERT, Christophe; WANG, Xuguang; SKALLI, Wafa; PILLET, Helene (Elsevier, 2015)The aim of this study was to propose a novel method for reconstructing the external body envelope from the low dose biplanar X-rays of a person. The 3D body envelope was obtained by deforming a template to match the surface ...
-
Communication avec acteAMABILE, Célia; CHOISNE, Julie; NÉROT, Agathe; SKALLI, Wafa; PILLET, Helene (European Society of Biomechanics, 2015)Rib cage volume and thorax density are useful both for clinical issues (Sverzellati et al. 2013) and for multi-segmental body modeling. In the latter case mean density is generally assumed, using data from Dempster et al ...