3-D Multi-Nodal Thermal Modelling for Fault-Tolerant Machine
Communication avec acte
Author
OUENZERFI, Safouene
1303 Laboratoire d'Automatique, de Mécanique et d'Informatique industrielles et Humaines - UMR 8201 [LAMIH]
1303 Laboratoire d'Automatique, de Mécanique et d'Informatique industrielles et Humaines - UMR 8201 [LAMIH]
BOUBAKER, Riadh
1303 Laboratoire d'Automatique, de Mécanique et d'Informatique industrielles et Humaines - UMR 8201 [LAMIH]
1303 Laboratoire d'Automatique, de Mécanique et d'Informatique industrielles et Humaines - UMR 8201 [LAMIH]
Abstract
Even if intrinsically a five-phase machine can work with one opened phase, thermal constraints (temperatures in windings and Permanent Magnets) impose to decrease the mean torque in faulty operation mode. In order to elaborate optimum control which ensures safety and maximum torque, it is necessary to estimate in real-time the temperatures induced by the currents imposed in the remaining healthy windings of the machine. For a five-phase prototype, a multi-nodal thermal modelling which can take into account irregular losses and flow distribution has been developed. It is based on Electromagnetic FEM results for the losses and CFD calculation analysis. Results are presented in normal and faulty operation modes.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureGONG, Jinlin; ZAHR, Hussein; TRABELSI, Mohamed; ASLAN, Bassel; SEMAIL, Eric; SCUILLER, Franck (Institute of Electrical and Electronics Engineers, 2018)In the context of traction drives with required torque transient capabilities and a classically wide flux weakening speed range, this paper gives design considerations of a particular Double-Polarity (DP) five-phase machine. ...
-
Communication avec acteThis paper presents a comparative evaluation of fault tolerant control strategies for a five-phase Permanent Magnet Synchronous Machine (PMSM) under an opened-phase fault mode. Two main classical Fault Tolerant Control ...
-
Communication avec acteThis paper analyses the copper losses due to the homopolar current of a five-phase open-end winding machine supplied by a 10-leg inverter and a single DC voltage source. This topology can have non-null high frequency ...
-
Communication avec acteFor a particular five-phase synchronous machine, this paper investigates the sensitivity of a vectorial control strategy on the required peak phase voltage whose value is fundamental for the choice of the DC bus voltage. ...
-
Communication avec acteThe paper studies the impact of first and third current-harmonic repartition in a five-phase Permanent Magnet machine whose Electromotive Forces (emfs) have first and third harmonics of the same amplitude. With a five-phase ...