Environment effect on internal fatigue crack propagation studied with in-situ X-ray microtomography

Article dans une revue avec comité de lecture
Author
ccHEBRARD, Louis
ccBUFFIERE, Jean-Yves
ccPALIN-LUC, Thierry
1002421 Institut de Mécanique et d'Ingénierie [I2M]
ccRANC, Nicolas
86289 Laboratoire Procédés et Ingénierie en Mécanique et Matériaux [PIMM]
ccMAJKUT, Marta
KING, Andrew
WECK, Arnaud

URI
http://hdl.handle.net/10985/24733
DOI
10.1016/j.msea.2023.145462
Date
2023
Journal
Materials Science and Engineering

Abstract

In the present study, physically short fatigue cracks initiated from an artificial internal notch under vacuum conditions are observed in smooth specimens made of titanium alloy. The crack initiated from such a notch is not in contact with the surface during the majority of its propagation. Another batch of artificially notched specimens in the same alloy having their internal notch linked with the surface to bring air to the initiated short crack were tested too. All the specimens were ultrasonically cycled with synchrotron micro-computed tomography acquisitions which were regularly acquired from crack initiation detection to final failure without demounting the specimen. The number of cycles to failure, the internal crack growth rate and the crack growth mechanisms of internal cracks are compared for propagation under either air conditions or in the core of the alloy (i.e. under vacuum environment). It is shown that the environment plays a key role in the explanation of the very low crack growth rate of internal short crack loaded at very low stress amplitude leading to the gigacycle regime

Files in this item

Name:
PIMM-Mat.Science-Palin-Luc-2023.pdf
Size:
4.475Mb
Format:
PDF
View/Open

Collections

  • Institut de Mécanique et d’Ingénierie de Bordeaux (I2M)
  • Laboratoire Procédés et Ingénierie en Mécanique et Matériaux (PIMM)

Related items

Showing items related by title, author, creator and subject.

  • In situ synchrotron ultrasonic fatigue testing device for 3D characterisation of internal crack initiation and growth 
    Article dans une revue avec comité de lecture
    MESSAGER, Alexandre; JUNET, Arnaud; ccPALIN-LUC, Thierry; ccBUFFIERE, Jean-Yves; EL MAY, Mohamed; GAILLARD, Yves; KING, Andrew; BONNIN, Anne; NADOT, Yves; ccRANC, Nicolas; ccSAINTIER, Nicolas (Wiley-Blackwell, 2020)
    This work presents a new ultrasonic fatigue testing device for studying the initiation and propagation mechanisms of internal microstructurally short fatigue cracks using in situ synchrotron tomography. Its principle is ...
  • Internal fatigue crack monitoring during ultrasonic fatigue test using temperature measurements and tomography 
    Article dans une revue avec comité de lecture
    ccRANC, Nicolas; ccMESSAGER, Alexandre; JUNET, Arnaud; ccPALIN-LUC, Thierry; ccBUFFIERE, Jean-Yves; ccSAINTIER, Nicolas; ELMAY, Wafa; MANCINI, L.; KING, Andrew; NADOT, Yves (Elsevier, 2022-09)
    Very high cycle fatigue fracture is often associated with internal crack propagation and one major problem to study the initiation and the propagation of this internal crack is to detect its initiation and quantify its ...
  • Deformation mechanisms at the tip of internal fatigue cracks in vacuum and in the presence of an air environment in a Ti alloy 
    Article dans une revue avec comité de lecture
    HÉBRARD, Louis; ccPALIN-LUC, Thierry; ccRANC, Nicolas; WECK, Arnaud; DOUILLARD, Thierry; BLANCHARD, Nicholas; DANCETTE, Sylvain; BUFFIERE, Jean-Yves (Elsevier BV, 2025-04)
    Ultrasonic fully reversed tension fatigue tests have been performed in the Very High Cycle Fatigue (VHCF) regime (Nr> 1E7 − 1E8 cycles) on Ti-6Al4V specimens containing a controlled internal notch. Two sets of samples have ...
  • About the effect of plastic dissipation in heat at the crack tip on the stress intensity factor under cyclic loading 
    Article dans une revue avec comité de lecture
    ccRANC, Nicolas; ccPALIN-LUC, Thierry; PARIS, Paul Croce; ccSAINTIER, Nicolas (Elsevier, 2013)
    Because of the reverse cyclic plastic zone at the crack tip, there is plastic dissipation in heat at the crack tip under cyclic loading. That creates a heterogeneous temperature field around the crack tip. A thermo-mechanical ...
  • About the effect of plastic dissipation in heat at the crack tip on the stress intensity factor under cyclic loading 
    Article dans une revue avec comité de lecture
    ccRANC, Nicolas; ccPALIN-LUC, Thierry; PARIS, Paul Croce; ccSAINTIER, Nicolas (Elsevier, 2014)
    Because of the reverse cyclic plastic zone at the crack tip, there is plastic dissipation in heat at the crack tip under cyclic loading. That creates a heterogeneous temperature field around the crack tip. A thermomechanical ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales