A Vectorial Approach for Generation of Optimal Current References for Multiphase Permanent-Magnet Synchronous Machines in Real Time

Article dans une revue avec comité de lecture
Author
ccSEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
ccKESTELYN, Xavier

URI
http://hdl.handle.net/10985/6738
DOI
10.1109/TIE.2011.2119454
Date
2011
Journal
IEEE Transactions on Industrial Electronics

Abstract

This paper deals with the generation of optimal current references for multiphase permanent-magnet (PM) synchronous machines in normal or fault mode (open-circuited phases). Current references are computed in order to keep a constant torque while minimizing instantaneous joule losses. In comparison with commonly used scalar methods, a vectorial approach makes it possible to reduce the number of computations in order to generate optimal current references in real time. In addition to this, since current references are expressed in terms of physical parameters of the machine, this approach can be used to evaluate the influence of machine parameters over the control performances. Finally, experimental results of a surface-mounted PM five-phase synchronous machine are provided in order to demonstrate the proposed strategy.

Files in this item

Name:
IES_from_ IEMDC 2009_kestelyn_ ...
Size:
805.6Kb
Format:
PDF
View/Open

Collections

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Related items

Showing items related by title, author, creator and subject.

  • Inversion-based control of electromechanical systems using causal graphical descriptions 
    Communication avec acte
    BARRE, Pierre-Jean; BOUSCAYROL, Alain; DELARUE, Philippe; DUMETZ, Eric; GIRAUD, Frédéric; HAUTIER, Jean-Paul; LEMAIRE-SEMAIL, Betty; ccSEMAIL, Eric; ccKESTELYN, Xavier (IEEE, 2006)
    Causal Ordering Graph and Energetic Macroscopic Representation are graphical descriptions to model electromechanical systems using integral causality. Inversion rules have been defined in order to deduce control structure ...
  • Modélisation causale pour la commande auto adaptée de machines alternatives triphasées en mode dégradé 
    Article dans une revue avec comité de lecture
    CREVITS, Yvan; LEMAIRE-SEMAIL, Betty; ccSEMAIL, Eric; ccKESTELYN, Xavier (Lavoisier, 2010)
    After a short historic of the multiphase machines and the state of the art of their open-circuited phase operation, this paper deals with a decoupled three-phase motor drive using a synchronous or induction machine. The ...
  • Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Short-Circuit Inverter Fault 
    Article dans une revue avec comité de lecture
    MEINGUET, Fabien; ccSEMAIL, Eric; ccKESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)
    Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...
  • Procédé de commande d'un moteur électrique à 3 phases alimentée indépendamment 
    Brevet
    BRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; ccSEMAIL, Eric; ccKESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)
    Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...
  • Multiphase system supplied by PWM VSI. A new technic to compute the duty cycles 
    Communication avec acte
    ccSEMAIL, Eric; HAUTIER, Jean-Paul; ccKESTELYN, Xavier (epe, 2003-10)
    When multi-phase machines with magnetic couplings between phases are supplied by triangle intersection PWM, there are parasitic currents. To solve the problem, it is necessary to use Space Vector Modulation. A SVM extended ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales