Flux-weakening operation of open-end winding drive integrating a cost effective high-power charger
Article dans une revue avec comité de lecture
Date
2013Journal
IET Electrical Systems in TransportationAbstract
In this paper, a three-phase drive with a six-leg Voltage Source Inverter (VSI) and an open-end winding Interior Permanent Magnet Synchronous Machine (IPMSM) designed for the traction of an electric vehicle is studied in flux-weakening operation. The topology allows the functionality of a high power charger to be obtained, without adding any other supplementary power devices. On the other hand, since there are three independent currents, the control structure has to handle not only the two dq current components but also a zero-sequence current. If neglected, in comparison with wye-coupled three-phase drive, this zero-sequence component can cause a higher maximum peak value of the phase currents, additional stator Joule losses, torque ripple, inverter voltage saturation and IGBT oversizing. The proposed control strategy consists in adapting a conventional method used for wye-connected machines particularly in flux-weakening operation. This strategy allows the closed-loop control of the zero-sequence current to be maintained in the whole speed range and therefore inverter saturation is avoided. Simulations and experimental results are presented and analyzed.
Files in this item
- Name:
- 2012 IET in press Flux-weakening ...
- Size:
- 1.495Mb
- Format:
- Embargoed until:
- 2013-03-07
Related items
Showing items related by title, author, creator and subject.
-
BrevetBRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; SEMAIL, Eric; KESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...
-
Article dans une revue avec comité de lectureSANDULESCU, Paul; MEINGUET, Fabien; BRUYERE, Antoine; SEMAIL, Eric; KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2014)This paper presents and compares control strategies for three-phase open-end winding drives operating in the flux-weakening region. A six-leg inverter with a single dc-link is associated with the machine in order to use a ...
-
Communication avec acteMEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; LU, Li; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (IEEE - Institute of Electrical and Electronics Engineers, 2012)A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SANDULESCU, Paul; SEMAIL, Eric; KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2013)A general method for fault detection and isolation is proposed and applied to inverter faults in drives of electric vehicles. This method is based on a change-detection algorithm, which allows multiple fault indices to be ...
-
Communication avec acteMulti-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of ...