Auto-adaptive fault tolerant control of a seven-phase drive
Communication avec acte
Abstract
This paper proposes an auto-adaptive current control that makes possible to reduce torque ripples of multi-phase machines in open-circuited phase conditions. Contrary to existing methods, current references are not recomputed and the control scheme used in normal mode is auto-adapted in order to run the machine with open-circuited phases. The number of degrees of freedom of the control scheme is adapted to the number of degrees of freedom of the drive and current controllers are auto-adaptive in order to reject the induced speed-dependent harmonic voltage disturbances that appear in fault-mode. Experimental results are presented to show the effectiveness of the proposed method.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureAfter a short historic of the multiphase machines and the state of the art of their open-circuited phase operation, this paper deals with a decoupled three-phase motor drive using a synchronous or induction machine. The ...
-
Communication avec acteThis paper deals with the generation of optimal current references for Multi-phase Permanent Magnet Machines with open-circuited phases. Compared to classical methods, the use of a vectorial approach makes it possible to ...
-
Communication avec acteThis paper proposes a simple way to control multi-phase drives in open-phase conditions. Contrary to existing methods, current references are not recomputed and the control scheme is kept the same to run in open-circuited ...
-
Communication avec acteBARRE, Pierre-Jean; BOUSCAYROL, Alain; DELARUE, Philippe; DUMETZ, Eric; GIRAUD, Frédéric; HAUTIER, Jean-Paul; LEMAIRE-SEMAIL, Betty; SEMAIL, Eric; KESTELYN, Xavier (IEEE, 2006)Causal Ordering Graph and Energetic Macroscopic Representation are graphical descriptions to model electromechanical systems using integral causality. Inversion rules have been defined in order to deduce control structure ...
-
Communication avec acteCet article est consacré à l’étude d’une méthode de commande d’une machine synchrone à aimant permanent à cinq phases associée à un onduleur de tension à MLI intersective. On s’intéresse au cas de la commande en mode normal ...