Fault Tolerant Control of a Seven-phase Drive by Degrees of Freedom Adaptation
Communication avec acte
Abstract
This paper proposes a simple way to control multi-phase drives in open-phase conditions. Contrary to existing methods, current references are not recomputed and the control scheme is kept the same to run in open-circuited phase condition. In order to work in fault-conditions, the number of degrees of freedom of the control scheme is adapted to the number of degrees of freedom of the drive. Since a particular attention has to be dedicated to the structure and controller tuning, harmonic content of induced perturbations in fault mode is exhibited. Simulation and experimental results are presented to show the effectiveness and the limitations of the proposed method.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureAfter a short historic of the multiphase machines and the state of the art of their open-circuited phase operation, this paper deals with a decoupled three-phase motor drive using a synchronous or induction machine. The ...
-
Communication avec acteThis paper deals with the generation of optimal current references for Multi-phase Permanent Magnet Machines with open-circuited phases. Compared to classical methods, the use of a vectorial approach makes it possible to ...
-
Communication avec acteCREVITS, Yvan; SEMAIL, Eric; KESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2010)This paper proposes an auto-adaptive current control that makes possible to reduce torque ripples of multi-phase machines in open-circuited phase conditions. Contrary to existing methods, current references are not recomputed ...
-
Communication avec acteBARRE, Pierre-Jean; BOUSCAYROL, Alain; DELARUE, Philippe; DUMETZ, Eric; GIRAUD, Frédéric; HAUTIER, Jean-Paul; LEMAIRE-SEMAIL, Betty; SEMAIL, Eric; KESTELYN, Xavier (IEEE, 2006)Causal Ordering Graph and Energetic Macroscopic Representation are graphical descriptions to model electromechanical systems using integral causality. Inversion rules have been defined in order to deduce control structure ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...