Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives
Communication avec acte
Date
2012Abstract
A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based on the unbalance of the phase currents and their instantaneous frequency. The method is applied to a five-phase permanent-magnet synchronous machine drive. Simulations and experiments validate the proposed method.
Files in this item
- Name:
- PAPER_ID_418_meinguet.pdf
- Size:
- 648.6Kb
- Format:
- Description:
- document article principal
Related items
Showing items related by title, author, creator and subject.
-
Communication avec acteMEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (EPE Conference, 2013)This paper presents a specific control strategy of double-ended inverter system for wide-speed range of open-winding five phase PM machines. Different virtual winding configurations (star, pentagon, pentacle and bipolar) ...
-
Communication avec acteLU, Li; ASLAN, Bassel; KOBYLANSKI, Luc; SANDULESCU, Paul; MEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2012)Multi-phase synchronous machines are more and more used in specific applications where high power density, low bus voltage, wide speed range and fault-tolerant capabilities are required. Due to the high number of degrees ...
-
Communication avec acteMulti-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...
-
BrevetBRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; SEMAIL, Eric; KESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...