Design and Experimental Validation of a Ducted Counter-rotating Axial-flow Fans System

Article dans une revue avec comité de lecture
Author
NOURI, Hussain
ccSARRAF, Christophe
134975 Laboratoire de Dynamique des Fluides [DynFluid]
REY, Robert
ccRAVELET, Florent
134975 Laboratoire de Dynamique des Fluides [DynFluid]
ccBAKIR, Farid

URI
http://hdl.handle.net/10985/8541
DOI
10.1115/1.4007591
Date
2012
Journal
Journal of Fluids Engineering

Abstract

An experimental study on the design of counter-rotating axial-flow fans was carried out. The fans were designed using an inverse method. In particular, the system is designed to have a pure axial discharge flow. The counter-rotating fans operate in a ducted-flow configuration and the overall performances are measured in a normalized test bench. The rotation rate of each fan is independently controlled. The relative axial spacing between fans can vary from 17% to 310%. The results show that the efficiency is strongly increased compared to a conventional rotor or to a rotor-stator stage. The effects of varying the rotation rates ratio on the overall performances are studied and show that the system has a very flexible use, with a large patch of high efficient operating points in the parameter space. The increase of axial spacing causes only a small decrease of the efficiency

Files in this item

Name:
Dynfluid-JFE-Nouri-2012.pdf
Size:
653.5Kb
Format:
PDF
Embargoed until:
2017-11-08
View/Open

Collections

  • Dynamique des Fluides (DynFluid)

Related items

Showing items related by title, author, creator and subject.

  • Experimental investigation on ducted counter-rotating axial flow fans 
    Communication avec acte
    NOURI, Hussain; ccRAVELET, Florent; ccSARRAF, Christophe; ccBAKIR, Farid (ASME, 2011)
    An experimental study on counter-rotating axial-flow fans was carried out. The fans of diameter D = 375 mm were designed using an inverse method. The counter-rotating fans operate in a ducted-flow configuration and the ...
  • Experimental study of the instationary flow between two ducted Counter-rotating rotors 
    Article dans une revue avec comité de lecture
    NOURI, Hussain; DANLOS, Amélie; ccRAVELET, Florent; ccSARRAF, Christophe; ccBAKIR, Farid (American Society of Mechanical Engineers, 2013)
    The purpose of this work is to study experimentally the aerodynamic characteristics of a subsonic counter-rotating axial-flow fans system operating in a ducted configuration. The fans of diameter D = 375 mm were designed ...
  • Experimental study of blade thickness effects on the global and local performances of a Controlled Vortex Designed axial-flow fan 
    Article dans une revue avec comité de lecture
    NOURI, Hussain; ccRAVELET, Florent; ccSARRAF, Christophe; ccBAKIR, Farid (Elsevier, 2011)
    The purpose of this work is to study the effects of blade thickness on the performances of an axial-flow fan. Two fans that differ only in the thickness of their blades were studied. The first fan was designed to be part ...
  • Experimental study of blade thickness effects on the overall and local performances of a Controlled Vortex Designed axial-flow fan 
    Article dans une revue avec comité de lecture
    SARRAF, Christophe; NOURI, Hussain; RAVELET, Florent; BAKIR, Farid (Elsevier, 2011)
    The purpose of this work is to study the effects of blade thickness on the performances of an axial-flow fan. Two fans that differ only in the thickness of their blades were studied. The first fan was designed to be part of ...
  • Experimental study of blade rigidity effects on the global and the local performances of a thick blades axial-flow fan 
    Communication avec acte
    NOURI, Hussain; ccRAVELET, Florent; ccSARRAF, Christophe; ccBAKIR, Farid (ASME, 2010)
    An experimental investigation on the aerodynamic performances of thick blades axial-flow fans was carried out in this study. Two fans are considered, the first one is rotomoulded (in plastic) and the second one is milled ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales